CZCL A-200AR Series Switching Power Supply
The CZCL A-200AR Series Switching Power Supply delivers 200W of reliable power with multiple voltage options (2.8V-5V). Designed for LED display applications, it features high efficiency, silent fanless operation, and built-in overload protection, ensuring stable performance and long-term durability. Models include A-200AR-2.8, A-200AR-3.3, A-200AR-3.8, A-200AR-4.2, A-200AR-4.5, and A-200AR-5.
Model Number |
A-200AR-2.8 ,A-200AR-3.3 ,A-200AR-3.8 ,A-200AR-4.2 ,A-200AR-4.5 ,A-200AR-5 |
---|
CZCL A-200AR Series Switching Power Supply Description
The CZCL A-200AR Series Switching Power Supply is a high-efficiency, fanless power solution designed specifically for LED display applications. This 200W power supply series provides multiple voltage output options, ensuring compatibility with various LED display configurations. With a compact design and natural convection cooling, it delivers stable performance, enhanced durability, and energy efficiency, making it an ideal choice for LED display systems.
This series includes the following models:
A-200AR-2.8 – 2.8V / 200W
A-200AR-3.3 – 3.3V / 200W
A-200AR-3.8 – 3.8V / 200W
A-200AR-4.2 – 4.2V / 200W
A-200AR-4.5 – 4.5V / 200W
A-200AR-5 – 5V / 200W
Product Features:
● High Efficiency & Stable Output – Provides consistent voltage regulation for enhanced LED display performance.
● Wide Voltage Options – Supports 2.8V to 5V outputs, catering to different LED screen power requirements.
● Silent Fanless Design – Utilizes natural convection cooling, ensuring quiet operation.
● Reliable Protection Mechanisms – Built-in short circuit, overload, and over-voltage protection to prevent damage.
● Compact & Lightweight – Slim design for easy integration into LED display cabinets.
● Long-lasting Durability – High-quality components for continuous, reliable operation.
CZCL A-200AR Series Switching Power Supply Specification
Model | A-200AR-2. 8 | A-200AR-3.3 | A-200AR-3.8 | A-200AR-4.2 | A-200AR-4.5 | A-200AR-5 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Voltage range | 180~264VAC | ||||||||||||
Input current | 230VAC/2.5A | |||||||||||||
Efficiency | ≥83% | ≥85% | ≥87% | ≥87% | ≥87% | ≥88% | ||||||||
Frequency range | 47~63HZ | |||||||||||||
Leakage current | <3.5mA/240VAC | |||||||||||||
Inrush current | Cold start 45A/230VAC | |||||||||||||
Output | DC voltage | 2.8V | 3.3V | 3.8V | 4.2V | 4.5V | 5V | |||||||
Rated current | 40A | 40A | 40A | 40A | 40A | 40A | ||||||||
Power | 112W | 132W | 152W | 168W | 180W | 200W | ||||||||
Voltage adj.range | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ||||||||
Ripple and noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | ||||||||
Set up,rise time | 2000ms,50ms/(230VAC) 100% load | |||||||||||||
Hold up time | 20ms/230VAC 100% laod | |||||||||||||
Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||||
Load regulation | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ||||||||
Voltage tolerance | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ||||||||
EMC | EMS | Design refer to:EN55024 ;EN61000-4-2,3,4,5,6,8,11 | ||||||||||||
Harmonic current | Design refer to:GB17625.1;EN61000-3-2,-3 | |||||||||||||
EMC | Design refer to:EN55022,Class A | |||||||||||||
Safety | Safety standard | Design refer to:GB4943/UL1012 | ||||||||||||
Withstand voltage | I/P-O/P:1.5KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA Testing time:1min | |||||||||||||
Isolation resistance | I/P-O/P:100M ohms; I/P-Case:100M ohms; O/P-Case:100M ohms | |||||||||||||
Protection | Over Voltage | / | ||||||||||||
Over load | 110~150% rated Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
Over Temperature | / | |||||||||||||
Short circuit | Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
Environment | Working temperature and humidity | -30~70℃ 20%~95%RH no condensing (refer to derating curve) | ||||||||||||
Storage temperature and humidity | -40℃~85℃; 10%~95%RH no condensing | |||||||||||||
Vibration | Frequency range 10 ~ 500Hz,acceleration 2G, each sweep cycle for 10min, 6 sweep cycles along X, y, Z axis | |||||||||||||
Shock | Acceleration: 20g, duration: 11ms, 3 impacts along X, y, Z axis | |||||||||||||
Altitude | 2000mtrs(for every 100 m higher than 2000 m, the ambient temperature decreases by 0.6 ℃) | |||||||||||||
Reliability | MTBF | 25℃:250000Hrs, MIL-217 Method | ||||||||||||
Others | Size | 208*59*31 mm(L*W*H) | ||||||||||||
Packing | 0.45Kg/piece,30pieces/carton,15.5KG/carton | |||||||||||||
Cooling mode | ☑ Free air □ Fan | |||||||||||||
Extension mode | □ three proofings □ terminal cover □ Low temperature start(-40℃) □ Others | |||||||||||||
Note | *In order to extend the lifetime, it is recommended to configure the load more than 30% of the remaining allowance. For example: the power of the device requires 100W, then use the power of not less than 130W. *Ripple test method: 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. *All electrical performance tests are performed at 25 C. *When the product is used in full load, the aluminum plate with an area of 400 * 400 * 3mm shall be added for auxiliary heat dissipation. *The power supply is a part of the components of the equipment system. All EMC tests are conducted by installing the sample on the metal plate. The power supply shall be confirmed with the terminal equipment for electromagnetic compatibility. | |||||||||||||
Download Resource:
CZCL-A-200AR-Series-Switching-Power-Supply-Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].
Reviews
There are no reviews yet.