CZCL A-200FAF-PH Series Switching Power Supply
$32.99
The CZCL A-200FAF-PH Series Switching Power Supply is an ultra-thin, high-efficiency power supply with active PFC, ensuring stable and reliable power conversion for LED displays. Available in A-200FAF-2.8PH, A-200FAF-3PH, A-200FAF-3.3PH, A-200FAF-3.8PH, A-200FAF-3.9PH, A-200FAF-4PH, A-200FAF-4.2PH, A-200FAF-4.5PH, A-200FAF-4.6PH, A-200FAF-4.8PH, and A-200FAF-5PH models, it guarantees optimal performance and longevity.
| Model Number |
A-200FAF-2.8PH ,A-200FAF-3PH ,A-200FAF-3.3PH ,A-200FAF-3.8PH ,A-200FAF-3.9PH ,A-200FAF-4PH ,A-200FAF-4.2PH ,A-200FAF-4.5PH ,A-200FAF-4.6PH ,A-200FAF-4.8PH ,A-200FAF-5PH |
|---|
CZCL A-200FAF-PH Series Switching Power Supply Description
The CZCL A-200FAF-PH Series Switching Power Supply is a high-performance, ultra-thin power supply with active Power Factor Correction (PFC), designed for LED display applications. This series provides stable and efficient power conversion, ensuring reliability and longevity for LED display systems. Available in multiple voltage options, it is engineered to meet various power requirements while maintaining low energy consumption and high efficiency.
Product Features:
● Ultra-Thin Design: Space-saving form factor ideal for compact LED display enclosures.
● Active PFC (Power Factor Correction): Enhances efficiency and reduces power consumption.
● Wide Voltage Range: Available in multiple voltage outputs to accommodate diverse LED module requirements.
● High Reliability & Stability: Built-in protection against overvoltage, overcurrent, and short circuits.
● Efficient Heat Dissipation: Advanced thermal management for consistent performance.
● Industrial Grade Components: Designed for durability and extended lifespan in harsh environments.
CZCL A-200FAF-PH Series Switching Power Supply Specification:
| Model | A-200FAF-2.8PH | A-200FAF-3PH | A-200FAF-3.3PH | A-200FAF-3.8PH | A-200FAF-3.9PH | A-200FAF-4PH | A-200FAF-4.2PH | A-200FAF-4.5PH | A-200FAF-4.6PH | A-200FAF-4.8PH | A-200FAF-5PH | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Input | Voltage range | 180~264VAC | ||||||||||
| Input current | 230VAC/1.35A | |||||||||||
| Efficiency | ≥83% | ≥83% | ≥84% | ≥85% | ≥85% | ≥85% | ≥85% | ≥86% | ≥86% | ≥87% | ≥87% | |
| Frequency range | 47~63HZ | |||||||||||
| Leakage current | <1mA/240VAC | |||||||||||
| Inrush current | Cold start 40A/230VAC | |||||||||||
| PFC | PF≥0.95 | |||||||||||
| Output | DC voltage | 2.8V | 3V | 3.3V | 3.8V | 3.9V | 4V | 4.2V | 4.5V | 4.6V | 4.8V | 5V |
| Rated current | 40A | 40A | 40A | 40A | 40A | 40A | 40A | 40A | 40A | 40A | 40A | |
| Power | 112W | 120W | 132W | 152W | 156W | 160W | 168W | 180W | 184W | 192W | 200W | |
| Voltage adj.range | / | / | / | / | / | / | / | / | / | / | / | |
| Ripple and noise | 200mVp-p | 201mVp-p | 202mVp-p | 203mVp-p | 204mVp-p | 205mVp-p | 206mVp-p | 207mVp-p | 208mVp-p | 209mVp-p | 200mVp-p | |
| Set up,rise time | 2000ms,50ms/230VAC 100% load | |||||||||||
| Hold up time | 20ms/230VAC 100% load | |||||||||||
| Line regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load regulation | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
| Output Voltage Accuracy | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
| EMC | EMS | Design refer to:EN55024 ;EN61000-4-2,3,4,5,6,8,11 | ||||||||||
| Harmonic current | Design refer to:GB17625.1;EN61000-3-2,-3 | |||||||||||
| EMC | Design refer to:EN55022,Class A | |||||||||||
| Safety | Safety standard | Design refer to:GB4943/UL1012 | ||||||||||
| Withstand voltage | I/P-O/P:3KVac/10mA; I/P-CASE:1.5KVac/10mA; O/P-CASE:0.5KVAC/10mA Testing time:1min | |||||||||||
| Isolation resistance | I/P-O/P: 50M ohms; I/P-Case:50M ohms; O/P-Case:50M ohms | |||||||||||
| Protections | Over Voltage | Voltage limiting type,110%~150% of rated voltage | ||||||||||
| Over load | 110~150% rated Hiccup mode, recovers automatically after fault condition is removed | |||||||||||
| Over Temperature | / | |||||||||||
| Short circuit | Protection after short circuit, auto-recovery after eliminating | |||||||||||
| Enviroment | Working temperature and humidity | -15~70℃ 20%~95%RH no condensing (refer to derating curve) | ||||||||||
| Storage temperature and humidity | -40℃~85℃; 10%~95%RH no condensing | |||||||||||
| Vibration | Frequency range 10 ~ 500Hz,acceleration 2G, each sweep cycle for 10min, 6 sweep cycles along X, y, Z axis | |||||||||||
| Shock | Acceleration: 20g, duration: 11ms, 3 impacts along X, y, Z axis | |||||||||||
| Altitude | 2000mtrs(for every 100 m higher than 2000 m, the ambient temperature decreases by 0.6 ℃ ) | |||||||||||
| Reliability | MTBF | 25℃:100000Hrs, MIL-217 Method | ||||||||||
| Others | Size | 190*82*30mm(L*W*H) | ||||||||||
| Packing | 0.36Kg/pc,30pcs/carton,11KG/carton | |||||||||||
| Cooling mode | ☑ Free air □ Fan | |||||||||||
| Extension mode | □ three proofings □ terminal cover □ Low temperature start(-40℃) □ Others | |||||||||||
| Remarks | *In order to extend the lifetime, it is recommended to configure the load more than 30% of the remaining allowance. For example: the power of the device requires 100W, then use the power of not less than 130W. *Ripple test method: 20MHz oscilloscope in power output terminal test, oscilloscope probe wire length is not more than 12mm, and input parallel 47uF electrolytic capacitors and 0.1uF high frequency capacitance probe. *All electrical performance tests are performed at 25 C. *When the product is used in full load, the aluminum plate with an area of 400 * 400 * 3mm shall be added for auxiliary heat dissipation. *The power supply is a part of the components of the equipment system. All EMC tests are conducted by installing the sample on the metal plate. The power supply shall be confirmed with the terminal equipment for electromagnetic compatibility. | |||||||||||
Download Resource:
CZCL-A-200FAF-PH-Series-Switching-Power-Supply-Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].































































Reviews