Specification of Delta LED Power Supply DPS-200PB-213-B
1 Electrical Requirements | ||
---|---|---|
ITEM | CONDITION | SPECIFICATION |
1.1 Input Characteristics: | ||
1.1.1 Input Rated Voltage: | 100Vac ~ 240Vac | |
1.1.2 Input Voltage Range: | Continuously | 90Vac~264Vac |
1.1.3 Input Rated Frequency: | 50Hz~60Hz | |
1.1.4 Input Frequency Range: | Continuously | 47Hz~63 Hz |
1.1.5 Input Current: | 100Vac@28A load | 4A(rms) Max. |
240Vac@full load | 2.5A(rms) Max. | |
1.1.6 Inrush Current: | Cold start, | |
115Vac@28A load | ≤35A | |
230Vac@full load | ≤60A | |
1.1.7 Efficiency: | 230Vac/50Hz @ full load | ³88% |
1.1.8 Power Factory: | 230Vac/50Hz @ full load 230Vac/50Hz @ 50W load | ³0.95 |
Power factor correction is active type | ³0.7 | |
1.1.9 Harmonic Standard: | 100Vac/60HZ @ 100W load / 28A load 230Vac/50HZ @ 100W load / full load | JIS C 61000‐3‐2 class D EN 61000‐3‐2 class D |
1.1.10 Power Saving: | Under no load condition | <6W |
1.1.11 AC Brown In/Out recovery: | @ 70% of full load | No damage |
1.1.12 Line Voltage Sag & Surge: | Sag: 115Vac‐80Vac‐115Vac(5000ms‐500ms‐5 000ms) 230Vac‐161Vac‐230Vac(5000ms‐500ms‐ | |
5000ms); | ||
Loading: 70% of max. load | ||
Surge: 132Vac‐155Vac‐132Vac(5000ms‐500ms‐5000ms); | The output voltage shall remain 95% of output regulation spec. | |
264Vac‐293Vac‐264Vac(5000ms‐500ms‐5000ms); | ||
Loading: 70% of max. load | ||
1.1.13 AC Cycle Drop Out: | AC line voltage: 115Vac‐0‐115Vac(1000ms‐10ms‐1000m s); 230Vac‐0‐230Vac(1000ms‐10ms‐1000m s); | |
Output load: 70% of max. load | The output voltage shall remain 95% of output regulation spec. | |
1.2 Output Characteristics: | ||
1.2.1 Output Rated Voltage: | Measured at the end of DC terminals | +4.6V |
1.2.2 Output Voltage Setting: | At the output end of DC terminals | +4.14V to +5.06V (10%) |
1.2.3 Output Current: | At constant voltage mode | 0A to 40A |
1.2.4 Output Voltage Regulation: | Input Voltage:90Vac~264Vac | +4.37V to +4.83V (5%) |
1.2.5 Line Regulation: | Percentage difference between 150Vac@full load and 264Vac@full load | £ ±0.2% |
1.2.6 Load Regulation: | Percentage difference between min. load and max. load at 230Vac. | £ ±1% |
1.2.7 Output Voltage Ripple and Noise: | Under any output load condition | £200mVp‐p |
0.1uF Ceramic Cap. and 10uF/50V Electrolysis Cap. Paralleled between the ends of output terminals. | ||
Bandwidth:20MHz | ||
1.2.8 Turn‐On Delay Time: | The output rise to 90% of the rated voltage | |
@25℃ 230Vac full load/115Vac 70% of full load | £ 3000ms; | |
@‐25℃ 230Vac full load/115Vac 70% of full load | £ 5000ms | |
1.2.9 Hold Up Time: | The output falls to 90% of the rated voltage. 230Vac input should be removed at phase 0°. Load : full load | ³ 10ms |
1.2.10 Rise Time: | The output rise from 10% to 90% of the | £ 100mS |
rated voltage at 115Vac/60Hz and 230Vac/50Hz | ||
1.2.11 Output Overshoot/Undershoot Voltage: | Under any output load condition | £ 13% of rated output voltage |
1.2.12 Load Transient Responses: | 1.Max. step load: | |
25% to 50% of full load and 50% to 75% of full load Frequency:50Hz~10kHz | Voltage tolerance limit 5% of Vo | |
Duty cycle:50% | ||
S/R=1A/us | ||
Cap. Load:1000uF | ||
2.Max. step load: | ||
25% to 75% of full load Frequency:50Hz~10kHz Duty cycle:50% | Voltage tolerance limit 10% of Vo | |
S/R=1A/us | ||
3.Max. step load:0A to Max. load Frequency:50Hz~10kHz | ||
Duty cycle:50% S/R=1A/us | No damage | |
1.2.13 Power De‐rating: | Refer to figure 1 and figure | |
2 | ||
1.2.14 No load Operation: | Input voltage: 90Vac ~ 264Vac, Output Load :0A | There is no specification of |
voltage range, and PSU shall operate normally. | ||
1.2.15 Maximum Capacitive Loading: | 6000uF @25℃ | Can start‐up |
1.3 Protection | ||
1.3.1 Short Circuit Protection: | The power supply can withstand continuous short at DC output and will | No broken, No smoke Auto recovery |
shut down under this condition. | ||
1.3.2 Over‐Voltage Protection: | The PSU will shut down that means no output while over voltage occurs at output terminals that caused by | £7.5V |
internal fault. | Auto recovery | |
1.3.3 Over Current Protection: | The power supply shall shut down automatically when over‐current occurs | £ 65A |
at output terminal. | Auto recovery | |
1.3.4 Over Temperature Protection: | The output shall be protected at over‐temperature condition. | No broken, No smoke Auto recovery OTP≥70℃(the ambient temperature)@115V / 22.4A load & @230V /32A |
load | ||
2 Environmental Characteristics: | ||
ITEM | CONDITION | SPECIFICATION |
2.1 Humidity: | Operating Humidity: | 10% ~ 90%RH |
Shipping/Storage Humidity: | 5% ~ 95%RH | |
2.2 Altitude: | Operating:0 to 5000M | |
Storage:0 to 5000M | ||
2.3 Cooling: | Ventilation cooling | |
2.4 Immunity: | ||
2.4.1 Electric Fast Transients(EFT): | Refer to IEC61000‐ 4‐4 | No function error |
Line to Line: +/‐ 2KV | No damage | |
2.4.2 Lightning Surge Immunity(Surge): | Refer to IEC 61000‐4‐5 Line to Line: +/‐ 1KV Line to Earth: +/‐ 2KV | |
Refer to IEC 61000‐4‐5 | No function error No damage | |
Line to Line: +/‐ 2KV Line to Earth: +/‐ 4KV | ||
No damage | ||
2.4.3 Electron Static Discharge(ESD): | Refer to IEC61000‐4‐2 | No function error. No damage |
Air Discharge: ± 15KV min. | ||
Contact Discharge: ±8KV min. | ||
2.5 Electromagnetic Interference (EMI): | a) FCC Part 15 Class B | |
b) EN55022 Class B | ||
2.6 Safety: | ||
2.6.1 Safety Standards: | UL60950‐1/IEC60950‐1/EN60950‐1 | |
GB4943.1‐2011 | ||
2.6.2 Safety Certificate: | CB/UL/TUV/CCC/CE/BSMI/ FCC | |
2.7 Leakage Current: | 240Vac / 50Hz | £ 1mA |
2.8 Earth Grounding: | Apply 30A current, test time: 60s (3s for production line) | <0.1 ohm |
2.9 Insulation Resistance: | Apply DC 500V between AC input and secondary. | >10MΩ |
2.10 Dielectric Strength: (Hi‐Pot): | 1. Between AC input and secondary apply AC 3000V, test time 1 minute. | Cut off current < 10mA. |
2. Between AC input and earth ground apply AC 1500V, test time 1 minute. | Cut off current < 10mA. Cut off current < 10mA. | |
3. Between secondary and earth ground apply DC 500V, test time 1 minute. For production line, test time of all above items will be 3 second. | ||
2.11 Temperature: | Operating | ‐25 to 70°C (refer to 1.2.13 power de‐rating curve,add not less than 450mm *450mm*3mm aluminum plate auxiliary cooling) (the PSU shall turn on at ‐40°C full load) |
Storage | ‐40 to +85°C |