Delta LED Power Supply DPS-500AB-57-A

$99.00

SKU: DPS500AB57A Categories: ,
DELTA
Description

Delta LED Power Supply DPS-500AB-57-A Specification

1 Electrical Requirements
ITEMCONDITIONSPECIFICATION
1.1 Input Characteristics:
1.1.1 Input Rated Voltage:100Vac~134.9V@80% of full load
135Vac~ 240Vac@full load
1.1.2 Input AC Voltage Range:90Vac~264VacOperate normal, function OK
300Vac@5sThe power supply shall withstand without damage
1.1.3 Input DC Voltage Range:127Vdc~370VdcOperate normal, function OK
1.1.4 Input Rated Frequency:50Hz~60Hz
1.1.5 Input Frequency Range:47Hz~63 Hz
1.1.6 Input Current:100Vac@80% of full load5A(rms) Max.
240Vac@full load2.6A(rms) Max.
1.1.7 Inrush Current:Cold start,≤30A
115Vac@80% of full load 230Vac@ full load≤60A
@25℃
1.1.8 Efficiency:230Vac/50Hz @ full load³94%
1.1.9 Power Factory:230Vac/50Hz @ full load³0.95
115Vac/60Hz @ 80% of full load Power factor correction is active type³0.98
1.1.10 Harmonic Standard:100Vac/60HZ@ 40%full load /80% of full loadJIS C 61000-3-2 class D EN 61000-3-2 class D
230Vac/50HZ@ 50%full load / full load
1.1.11 Power Saving:115Vac/60Hz<6W
230Vac/50Hz
Under no load condition
1.1.12 AC Brown In/Out recovery:@ 80% of full loadNo damage
1.1.13 Line Voltage Sag & Surge:Sag:The output voltage shall remain 95% of output regulation spec.
115Vac-80Vac-115Vac(5000ms-500ms-5000ms)
230Vac-161Vac-230Vac(5000ms-500ms-5000ms);
Loading: 80% of max. load Surge:
132Vac-155Vac-132Vac(5000ms-500ms-5000ms);
264Vac-293Vac-264Vac(5000ms-500ms-5000ms);
Loading: 80% of max. load
1.1.14 AC Cycle Drop Out:AC line voltage:The output voltage shall remain 95% of output regulation spec.
115Vac-0-115Vac(1000ms-10ms-1000ms);
230Vac-0-230Vac(1000ms-10ms-1000ms);
Output load: 80% of max. load
1.2 Output Characteristics:
1.2.1 Output Rated Voltage:Measured at the end of DC terminals+24V
1.2.2 Output Current:90Vac~134.9Vac&127Vdc~179.9Vdc0A to 16.72A(80% load)
135Vac~264Vac&180Vdc~370Vdc0A to 20.9A(full load)
1.2.3 Output Voltage Regulation:Input Voltage:90Vac~264Vac+22.8V to +25.2V (5%)
1.2.4 Output powerMaximum continue501.6W
1.2.5 Line Regulation:Percentage difference between 135Vac@full load and 264Vac@full load£ ±0.3%
1.2.6 Output Voltage Ripple and Noise:Under any output load condition 0.1uF Ceramic Cap. and 47uF/50V Electrolysis Cap. Paralleled between the ends of output terminals. Bandwidth:20MHz£240mVp-p @25℃
1.2.7 Turn-On Delay Time:The output rise to 90% of the rated voltage @25℃ 230Vac full load/115Vac 80% of full load @-25℃ 230Vac full load/115Vac 80%£ 1000ms
1.2.8 Hold Up Time:The output falls to 90% of the rated voltage.input should be removed at phase 0°. 230Vac/115Vac with 80% of full load³ 10ms
1.2.9 Rise Time:The output rise from 10% to 90% of the rated voltage at 115Vac/80% of full load and 230Vac/ full load£ 50mS
1.2.10 Output Overshoot/Undershoot Voltage:Under any output load condition£ 10% of rated output voltage
1.2.11 Load Transient Responses:1.Max. step load:
25% to 50% of full load and 50% to 75% of full load Frequency:50Hz~10kHzVoltage tolerance limit 5% of Vo
Duty cycle:50% S/R=1A/us
Cap. Load:1000uF
2.Max. step load:
25% to 75% of full load Frequency:50Hz~10kHz Duty cycle:50% S/R=1A/usVoltage tolerance limit 5% of Vo
Cap. Load:1000uF
3.Max. step load:0A to Max. load Frequency:50Hz~10kHzNo damage
Duty cycle:50% S/R=1A/us
Cap. Load:1000uF
1.2.12 Power De-rating:Refer to figure 1 and figure 2
1.2.13 No load Operation:Input voltage: 90Vac ~ 264Vac, Output Load :0AThere is no specification of
voltage range, and PSU shall operate normally.
1.2.14 Maximum Capacitive Loading:6000uF @25℃Can start-up
1.2.15 Loop Gain115Vac 60Hz/Load:0.2A/80% of full load 230Vac 50Hz/Load:0.2A/full load1. Phase margin > 45deg
2. Gain margin < -10dB 100% Derating
1.2.16RL1 Thermal
1.3 Protection
1.3.1 Short Circuit Protection:The power supply can withstand continuous short at DC output and will shut down and then auto recovery while remove fault condition.No broken, No smoke Auto recovery
1.3.2 Over-Voltage Protection:The PSU will shut down that means no output while over voltage occurs at output terminals that caused by internal fault.26.4V~31.2V
1.3.3 Over Current Protection:The power supply shall shut down automatically when over-current occurs at output terminal at 25’C.26A~ 38A Auto recovery
1.3.4 Over Temperature Protection:The output shall be protected at over-temperature condition.No broken, No smoke Auto recovery OTP>70℃(the ambient temperature)@115V /13.38A load & @230V/16.72A load
2 Environmental Characteristics:
ITEMCONDITIONSPECIFICATION
2.1 Humidity:Operating Humidity:20% ~ 95%RH
Shipping/Storage Humidity:10% ~ 95%RH
2.2 Altitude:Operating:0 to 5000M /Storage:0 to 5000M
2.3 Cooling:Ventilation cooling
2.4 Immunity:
2.4.1 Electric Fast Transients(EFT):Refer to IEC61000- 4-4No function error
Line to Line: +/- 2KVNo damage
2.4.2 Lightning Surge Immunity(Surge):Refer to IEC 61000-4-5 Line to Line: +/- 1KV Line to Earth: +/- 2KV
Refer to IEC 61000-4-5No function error No damage
Line to Line: +/- 2KV Line to Earth: +/- 4KVNo damage
2.4.3 Electron Static Discharge(ESD):Refer to IEC61000-4-2No function error. No damage
Air Discharge: ± 15KV min.
Contact Discharge: ±8KV min.
2.5 Electromagnetic Interference (EMI):Class A,10db
2.6 Safety:
2.6.1 Safety Standards:UL60950-1/IEC60950-1/EN60950-1
GB4943.1-2011/ IEC62368-1
2.6.2 Safety Certificate:CB/UL/TUV/CCC/CE/BSMI/ KC/FCC
2.7 Leakage Current:240Vac / 50Hz£ 1mA
2.8 Earth Grounding:Apply 30A current, test time: 60s (3s for production line)<0.1 ohm
ITEMCONDITIONSPECIFICATION
2.9 Insulation Resistance:Apply DC 500V between AC input and secondary,AC input and FG,secondary and FG>100MΩ
2.10 Dielectric Strength: (Hi-Pot):1.  Between AC input and secondary apply AC 3KV, test time 1 minute.Cut off current < 10mA.
2.  Between AC input and earth ground apply AC 1.5KV, test time 1 minute.Cut off current < 10mA. Cut off current < 10mA.
3.  Between secondary and earth ground apply DC 500V, test time 1 minute.
For production line, test time of all above items will be 3 second.
2.11 Temperature:Operating-25 to 70°C(refer to 1.2.11 power de-rating curve,add not less than 700mm *700mm*5mm aluminum plate auxiliary cooling)(the PSU shall turn on at -40°C full load)
Storage-40 to +85°C
2.12 MTBF:115Vac/60Hz load/16.72A @25℃ 230Vac/50Hz load/20.9A @25℃168,000hrs
2.13 CAP. Life:AC/115V, load/16.72A@40℃>3 years
2.14 Burn-In:AC/115V, load/10.45A, 40℃4hours ,No function error
3 Mechanical
3.1 Dimension:237*81*31 (mm)
3.2 Coating:PWB front and back sides are sprayed additional adhesive coating.
3.3 Assembly:The PSU should be mounted on a 700x700x5 AL plate or an equal dimension enclosure to get better cooling shown as below figure.
3.4 Screw Torque:AC Connector Screw Torque Suggestion:13-18kgf.cm DC Connector Screw Torque Suggestion:9-11kgf.cm
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Delta LED Power Supply DPS-500AB-57-A”

Your email address will not be published. Required fields are marked *

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].