Goldpower GPAD201M12-1K Series Switching Power Supply
The 90-264VAC Full Range Voltage Input LED Display Power Supply is a high-efficiency, reliable power supply that is perfect for a variety of applications.
$39.99 – $42.99
Goldpower GPAD201M12-1K Series Switching Power Supply
The GPAD201M12-1K Series 90-264VAC Full Range Voltage Input LED Display Power Supply is a high-efficiency, reliable power supply that is perfect for a variety of applications. With its wide input voltage range of 90-264VAC, it can be used in a variety of countries and regions around the world. The power supply also features a wide operating temperature range of -40 to +70 degrees Celsius, making it suitable for use in a variety of climates.
The power supply features a high power factor of 0.95, which helps to reduce energy consumption. It also features a variety of protection mechanisms to ensure the safety of your equipment, including output over-voltage protection, output over-current protection, output short-circuit protection, and over-temperature protection.
The power supply is made with high-quality components and is built to last. It is backed by a 3-year warranty, which gives you peace of mind knowing that your investment is protected.
Type Number | Input voltage range (Vac) | Output voltage range (Vdc) | Output current range (A) | Rated output power (W) | Overall dimensions (L * W * H) | |
---|---|---|---|---|---|---|
GPAD201M12-1K | 90-264 | 12 | 0-17 | 200 | 165*46*26mm | |
GPAD201M15-1K | 90-264 | 15 | 0-13.3 | 200 | 165*46*26mm | |
GPAD201M24-1K | 90-264 | 24 | 0-8.3 | 200 | 165*46*26mm | |
GPAD201M36-1K | 90-264 | 36 | 0-5.5 | 200 | 165*46*26mm | |
GPAD201M48-1K | 90-264 | 48 | 0-4.2 | 200 | 165*46*26mm | |
GPAD201M54-1K | 90-264 | 54 | 0-3.7 | 200 | 165*46*26mm | |
GPAD201M56-1K | 90-264 | 58 | 0-3.4 | 200 | 165*46*26mm | |
2.1 Input characteristics | ||||||
Parameter | Minimal | Typical | Max | Unit | Comment | |
Operating temperature | -40 | 70 | °C | |||
Storage ambient temperature | -40 | 85 | °C | |||
Operating relative humidity | 20 | 95 | % | No condensation | ||
Store relative humidity | 5 | 95 | % | No condensation | ||
Altitude | 5000 | m | High temperature drop under service environment at 3000-4000m Decrease by 1 ℃ for every 200 m increase | |||
Atmospheric pressure | 70 | 106 | KPa | |||
Heat dissipation mode | Natural conduction and heat dissipation | |||||
Input voltage range | 90 | 220 | 264 | Vac | ||
Input current | 3 | A | ||||
Input rush current | 50 | A | 220Vac input, output full load | |||
Enter the frequency | 47 | 50 | 63 | Hz | Full range normal operation | |
Power factor | 0.95 | 220Vac input, output full load | ||||
Harmonic distortion | 15 | % | 230Vac input, output half load or full load | |||
2.2 Output characteristics | ||||||
Parameter | Minimal | Typical | Max | Unit | Comment | |
Output voltage | +12V | Vdc | The output voltage is set according to the factory requirements. | |||
Output current range | 0 | 17 | A | |||
Output Power | 200 | W | ||||
Output efficiency | 91 | % | 220Vac input, full load output | |||
Ripple (peak-to-peak) | 200 | m Vp-p | At rated input/output, add and combine 0.11F ceramic chip capacitor and One each 10 10μF high frequency electrolytic capacitor with 20 MHz bandwidth Measure. | |||
Load regulation | ±2 | % | ||||
Source adjustment rate | ±0.5 | % | ||||
Temperature coefficient | ±0.03 | %/℃ | ||||
Startup and shutdown overshoot | ±10 | % | ||||
Dynamic Response Overshoot | ±5 | % | 25% -50% -25% or 50% -75% -50% load transformer The load mutation rate is 0.1A/s, which is calculated by the part exceeding the output voltage stabilization accuracy range. | |||
Dynamic Response Recovery Time | 200 | ūS | ||||
Power-on output delay | 2 | S | Input 220Vac, output full load | |||
Isolation function | The two power supplies can be used in parallel. Use to get better For the current sharing effect, the current sharing buses of the two power supplies need to be connected in parallel. | |||||
2.3 Protection characteristics | ||||||
Parameter | Minimal | Typical | Max | Unit | Comment | |
Output overvoltage protection | 13.5 | V | 220Vac input, output half load test, hiccup | |||
Output overcurrent protection | 17.5 | A | Hiccups, self-healing | |||
Short circuit protection | Have | Can be short-circuited for a long time; The output positive and negative poles can be recovered after the abnormal short circuit is removed | ||||
Resume normal output | ||||||
Over-temperature protection | 90 | 110 | °C | The power protection mode is hiccup mode; When the ambient temperature returns to the normal operating temperature of the power supply, the hiccup mode is contacted and the power supply output is normal. | ||
High temperature protection | When the power supply is working, the heat of the power supply is dissipated by the shell. Please do not touch it. Power supply housing to avoid scalding | |||||
2.4 Safety regulations and insulation level | ||||||
Parameter | Standard requirements | Comment | ||||
Input-output | 3000Vac/≤10mA/1min | |||||
Input-Earth | 1500Vac/≤10mA/1min | No flashover, no breakdown | ||||
Output-Earth | 500Vdc/≤10mA /1min | |||||
Grounding resistance | <0.1Ω | Experimental current: 32 A, experimental time: 120 S | ||||
Insulation resistance | ≥10MΩ | Under normal atmospheric pressure, the relative humidity is 90% and the test voltage is DC 500 V, the insulation resistance of power supply input to output, input to ground and output to ground shall not be lower than 10MΩ | ||||
Leakage current | ≤0.7m A | Input 264VAC 50HZ | ||||
2.5 Electromagnetic compatibility project test | ||||||
Project | Indicator requirements | Standard | ||||
Air discharge ± 8 KV | IEC 61000-4-2 (Criterion A) | |||||
Electrostatic Immunity (ESD) | Contact discharge ± 6 KV | IEC 61000-4-2 (Criterion A) | ||||
Radiated immunity (RS) | Test frequency: 80MHz ~ 2GHz Electric field intensity: 3V/m; Amplitude modulation: 80% AM (1kHz) | IEC 61000-4-3 (Criterion A) | ||||
Conducted Immunity (CS) | Test frequency: 0.15 MHz ~ 80 MHz, test intensity: 3 V, amplitude modulation: 80% AM (1kHz) | IEC 61000-4-6 (Criterion A) | ||||
Fast Transient Burst (EFT/B) | ± 2kV, repetition frequency: 5KHz & 100KHz | IEC 61000-4-4 (Criterion A) | ||||
Surge (SURGE) | AC power port: line ± 1 kV (internal resistance 2 Ω; Line ground ± 2kV (internal resistance: 12Ω) | IEC 61000-4-5 (Criterion A) | ||||
Conducted disturbances (CE) | CLASS B (Note 2) | CISPR22 ï¼› EN55022 ï¼› GB9254 | ||||
Radiated disturbance (RE) | CLASS B (Note 2) | |||||
2.6 Others | ||||||
Vibration | Frequency from 10Hz to 55Hz (sine sweep), amplitude 0.35 mm | |||||
Impact | Peak acceleration of 150 m/s2for 11 ms | |||||
Collision experiment | Collision waveform: half sine wave; Peak acceleration: 180m/S2; Pulse width: 6ms; Collision direction: 6 directions; Collision times Number: 100 times in each direction. | |||||
Static pressure test | TL=Wt×(S-1)×F×9.8(N) Where: TL: the applied pressure value, unit: N; Wt: the weight of the package itself, unit: kg; S: the number of stacking layers allowed, select the maximum number of stacking layers; F: safety factor, usually 5; The pressure is applied for 2 H. | |||||
Moisture-proof | GB/T2423.4-1993 Alternate damp heat test, 24 ~ 45 ℃, 95% RH, 48h | |||||
Mildew proof | Mould test, grade 2 | |||||
MTBF | ≥150,000h | |||||
Odor requirements | Do not produce peculiar smell and smell harmful to health. | |||||
2.7 Routine environmental test | ||||||
Project | Indicator requirements | Standard | ||||
Low temperature working test | -25 ℃, 24h, temperature change rate 1 ℃/min | GB _ T 2423.1-2008 Test Ae | ||||
High temperature working test | 55 ℃, 24h, temperature change rate 1 ℃/min | GB _ T 2423.2-2008 Test Be | ||||
Low temperature storage test | -40 ℃, 24h, temperature change rate 1 ℃/min | GB _ T 2423.1-2008 Test Ab | ||||
High temperature storage test | 85 ℃, 24h, temperature change rate 1 ℃/min | GB _ T 2423.2-2008 Test Bb | ||||
Alternating damp heat test | Alternating damp heat test, temperature 25 ~ 55 ℃, humidity 93%, 2 cycles, 48 H in total. | GB_T 2423.4-2008 | ||||
Temperature change test | -25 ~ 55 ℃, 2 cycles, the holding time of high and low temperature is 3 hours respectively, and the temperature change rate is 1 ℃/min | GB _ T 2423.22-2012 Test Nb | ||||
Bare metal crash test | A half-sine pulse; Peak acceleration 20g; Pulse width 11 ms; Positive and negative directions of three axial directions; 100 times in each direction. | |||||
Bare metal drop test | Drop height: 0.10 m. Part I: for all placement surfaces, each surface shall be dropped four times; Part II: All placement surfaces, one free drop per surface. | |||||
Low temperature start-up test | -25 ℃, start 3 times. It can be started normally, drop is allowed during the starting process, and the output voltage after starting meets the requirements of the output voltage range. Test at input maximum, minimum and typical values | |||||
2.8 Mechanical properties | ||||||
Overall dimension (L * W * H mm) | 165*46*26 | |||||
Weight (kg) | 0.3Kg |
Additional information
Type Number | GPAD201M12-1K, GPAD201M15-1K, GPAD201M24-1K, GPAD201M36-1K, GPAD201M48-1K, GPAD201M54-1K, GPAD201M56-1K |
---|
Reviews
There are no reviews yet.