Goldpower GPAD201M5-1C LED Display Switching Power Supply
$59.99
The Goldpower GPAD201M5-1C is a 200W single-output LED switching power supply with wide input voltage, adjustable 4.2–5V output, and built-in protection features for safe, reliable operation.
Goldpower GPAD201M5-1C LED Display Switching Power Supply Description
The Goldpower GPAD201M5-1C is a high-performance, single-output switching power supply designed for LED display applications. With a wide input voltage range of 90-264Vac, it delivers stable and reliable power for small to large LED modules. The unit incorporates multiple protection features, including overcurrent, short-circuit, overvoltage, and over-temperature protection, ensuring safe operation under a variety of conditions.
Product Features:
Wide Input & Stable Output:
• Supports AC input voltage from 90–264V, suitable for various international power grids.
• Adjustable DC output voltage from 4.2–5V, allowing compatibility with multiple LED display modules.
• Single-output design with 200W rated power for high-efficiency operation.
• Low load regulation of ±1% ensures consistent power delivery under varying load conditions.
• Voltage stabilization accuracy of ±5% provides a reliable output for sensitive LED components.
• Source adjustment rate ±0.5% minimizes voltage fluctuations, keeping displays stable.
• Noise + ripple controlled within 200mV (peak-to-peak), ensuring high-quality LED performance.
Comprehensive Protection Features:
• Overcurrent protection to prevent damage from excessive load.
• Short-circuit protection for output safety.
• Overvoltage protection set at 6–6.5V to safeguard LED modules.
• Output current limiting protection between 58–70A for system safety.
• Over-temperature protection with a central test point to monitor heat levels.
• Surge and fast transient protection maintain power stability during voltage spikes.
High Efficiency & Dynamic Performance:
• High conversion efficiency of 86–88% at 220Vac under full load reduces energy loss.
• Fast dynamic response with overshoot ±5% for 25%-50%-25% or 50%-75%-50% load changes.
• Maintains stable output during rapid load fluctuations for LED displays in live applications.
• Optimized thermal management reduces heat buildup and prolongs product lifespan.
Safety & Compliance Certified:
• EMC tested: radiated emission, conducted interference, electrostatic discharge (ESD).
• Surge, fast transient burst, vibration, impact, and flicker immunity ensure stable operation.
• Current harmonic emission within acceptable limits for industrial standards.
• Meets international safety standards for information technology equipment.
• Proper insulation levels guarantee user safety and compliance with electrical codes.
Reliable Industrial Design:
• Rugged and compact enclosure suitable for installation inside LED cabinets or control racks.
• Built to operate in a wide range of ambient temperatures and industrial environments.
• Long-term durability ensures reliable performance in continuous operation for LED displays.
• Ideal for small, medium, and large-scale LED display projects in commercial, rental, or outdoor applications.
Versatile Applications:
• Compatible with single-color, dual-color, and full-color LED modules.
• Supports digital signage, indoor/outdoor advertising screens, stadium displays, and rental stage LED walls.
• Suitable for environments requiring uninterrupted, stable power for high-performance LED panels.
Goldpower GPAD201M5-1C LED Display Switching Power Supply Specification:
| Environment | |||||
|---|---|---|---|---|---|
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Operating temperature(Casing center point temperature) | -25 | 65 | 80 | °C | |
| Storage temperature | -25 | 25 | 100 | °C | |
| Relative humidity | 5 | 95 | % | No condensation | |
| Altitude | 0 | 4000 | m | Wherein, the high temperature drop under the service condition of 3000-4000 m, Decrease by 1 ℃ for every 200 m increase | |
| Heat dissipation mode | Natural conduction and heat dissipation | ||||
| Input | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| AC input voltage range | 90 | 110/220 | 264 | Vac | |
| AC input voltage frequency | 47 | 50/60 | 63 | Hz | |
| Power factor | 0.95 | 220Vac full load | |||
| Input rush current | 50 | A | 220Vac full load/cold | ||
| AC input system | Single-phase input L、N | Supports single phase | |||
| Basic output characteristics | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output voltage range | 4.2 | 4.6 | 5 | Vdc | Adjustable output voltage |
| Output setting voltage | 4.55 | 4.6 | 4.65 | Vdc | |
| Output current range | 0 | 40 | A | Full voltage input range | |
| Load regulation | ±1 | % | Rated voltage input, full load variation | ||
| Voltage stabilization accuracy | ±5 | % | Full voltage input range/full load output | ||
| Source adjustment rate | ±0.5 | % | Rated current output, full voltage range variation | ||
| Noise + Ripple (peak-to-peak) | 200 | mV | The test is carried out within the full input voltage and load range, and a 0.1uF ceramic capacitor or a gold film capacitor and a 10uF electrolytic capacitor are added at the output end during the test, and the bandwidth of the oscilloscope is 20 MHz | ||
| Other output characteristics | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output Power | 200 | W | |||
| Output efficiency | 86 | 88 | % | 220Vac input, output full load, normal temperature test | |
| Dynamic Response Overshoot | ±5 | % | 25% -50% -25% or 50% -75% -50% load change, | ||
| Current change rate 0.1A/us, period 4ms | |||||
| The output suddenly applies 100% load from no load, and the output jumps back and forth from full load to no load (the jump time is 5ms, and it can be maintained for several cycles after the jump). Measure the output voltage waveform. The module shall not have output oscillation, and the overshoot of output voltage shall not exceed 10% of the setting value of output voltage. | |||||
| Dynamic Response Overshoot | ±10 | % | |||
| Temperature coefficient | ±0.02 | %/℃ | Rated output voltage and output current, full operating temperature range | ||
| Power-on output delay | 2 | S | Full load test at 220Vac | ||
| Startup and shutdown overshoot | ±10 | % | Full voltage input range, full load output | ||
| Output Voltage Rise Time | 100 | ms | Rated input/rated output | ||
| With capacitive load | 4700 | 10000 | uF | Full voltage full load range | |
| Protect | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output overvoltage protection point | 6 | 6.5 | V | Output is locked | |
| Output current limiting protection point | 58 | 70 | A | Overcurrent hiccup, output 4.6V test | |
| Output short circuit protection | Long-term short circuit and self-recovery | ||||
| Over-temperature protection | 80 | 95 | ℃ | Over temperature shutdown, recoverable. The test point is the center of the power supply enclosure point | |
| EMC and others | |||||
| Parameter | Standard requirements | ||||
| Radiated Emission (CE) | EN55022 - Class A | ||||
| Conducted interference (RE) | EN55022 - Class A | ||||
| Electrostatic discharge (ESD) | EN61000-4-2 Contact discharge: ± 4 KV, air discharge: ± 8 KV. (Criterion B) | ||||
| Radiated immunity (RS) | EN61000-4-3 LEVEL 3; Criteria A; 10V/m field strength | ||||
| Conducted Immunity (CS) | EN61000-4-6 (the output end of the power module shall also be tested) LEVEL 3; Criterion A: 10V | ||||
| Surge (SURGE) | EN61000-4-5 Input: line-to-line 1 KV, line-to-ground 2 KV | ||||
| Fast Transient Burst (EFT/B) | ± 2KV, LEVEL 3, Criterion B IEC61000-4-4 | ||||
| Frequency 1-4Hz, acceleration spectral density 0.0001 G2/Hz; Frequency 4-100Hz, acceleration spectral density 0.01 G2/Hz; Frequency | |||||
| Vibration | 100-200Hz, acceleration spectral density 0.001 G2/Hz; Total RMS acceleration: 0.781 Grms; Test axial direction: 3 axial directions. Test time: 30 min in each axial direction. | ||||
| Impact | Impulse waveform: half sine wave; Peak acceleration: 300m/S2; Pulse width: 6ms; Axial direction of impact: 6 directions; Impact Times: 3 times in each direction | ||||
| Voltage fluctuation and flicker | Pst≤1.0 dc≤3% | ||||
| P1t≤0.65 dmax≤4% D (t) value exceeds 3.3% ≤ 200ms | |||||
| Current harmonic emission | CLASS A IEC61000-3-2 {6} | ||||
| Acoustic noise | 55dB(A); Test distance 1m | ||||
| MTBF | MTBF≥200,000h | ||||
| Odor requirements | Do not produce peculiar smell and smell harmful to health. | ||||
| Safety regulations and insulation level | |||||
| Parameter | Standard requirements | Comment | |||
| Input-output | 3000Vac/10mA//1min | No flashover, no breakdown | |||
| Input-Earth | 1500Vac/10mA//1min | No flashover, no breakdown | |||
| Output-Earth | 500Vdc/10mA//1min | No flashover, no breakdown | |||
| Insulation resistance | ≥10MΩ | Under normal atmospheric pressure, relative humidity < 90%, test voltage 500 Vdc, power input vs. output, input Insulation resistance to ground and output to ground ≥ 10 MΩ | |||
| Leakage current | <1mA | ||||
| Mechanical properties | |||||
| L * W * H | 145*78*26mm | ||||
| Weight (kg) | ≤1Kg | ||||
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].































































Reviews
There are no reviews yet.