Goldpower GPAD201M5-1K Series LED Display Power Supply

$63.99$65.99

The GPAD201M5-1K power supply is a high-density device with a wide input voltage range of 90~264VAC, efficient power factor correction, and various protection features, making it perfect for a variety of applications.

Type Number

GPAD201M4-1K

,

GPAD201M5-1K

,

GPAD201M6-1K

Output Voltage

DC4.2V

,

DC4.5V

,

DC4.6V

,

DC5V

SKU: GPAD201MX1K Categories: ,
GOLDPOWER
Description

Goldpower GPAD201M5-1K Series LED Display Power Supply Description

GPAD201M5-1K power supply, part of the GPAD201M series, is designed and manufactured to meet strict safety requirements and the safety standards of information technology equipment. With a wide input voltage range of 90~264VAC, the GPAD201M5-1K can handle a range of input voltages, making it suitable for use in a variety of applications. The power supply also features power factor correction (PFC) greater than or equal to 0.95, ensuring high efficiency and low harmonic distortion.
The GPAD201M5-1K is also equipped with various protection features such as output overvoltage protection, output overcurrent protection, output short-circuit protection, and over-temperature protection. This ensures safe and reliable operation, while the ultra-low contact leakage current of the entire device being ≤0.5mA can reduce the need for leakage air switch configuration.

The power supply has a compact size of 165*46*26mm, which is among the smallest in the industry, and uses long-life 125°C solid capacitors at the output. The LED light working status indication makes it easy to monitor the status of the power supply.

In terms of output characteristics, the GPAD201M5-1K power supply provides a voltage range of 4.2~5.0VDC, output current up to 40A, and output power up to 200W. The power supply’s high efficiency, up to ≥90%, ensures minimal energy waste and low operating costs.

The GPAD201M5-1K power supply also features dynamic response overshoot of ±5% and dynamic response recovery time of 200μs, making it suitable for applications with rapidly changing loads. In addition, the power-on output delay is only 2s, making it quick to start up.

This power supply is the perfect choice for applications where high power density, safety, reliability, and low energy waste are required.

1. List of models
ModelInput voltage VACConfigurable output Voltage VDCOutput power Flow AMaximum output work Rate WOverall dimensions (L * W * H)
GPAD201M4-1K90-2643.3~4.040160165*46*26mm
GPAD201M5-1K90-2644.2~5.040200165*46*26mm
GPAD201M6-1K90-2645.5~640200165*46*26mm
2.1 Working environment
ParameterMinimalTypicalMaxUnitComment
Operating temperature-2555°C
Storage ambient temperature-4085°C
Operating relative humidity2095%No condensation
Store relative humidity595%No condensation
Altitude5000mHigh temperature drop under service environment at 3000-4000m. Decrease by 1 ℃ for every 200 m increase
Atmospheric pressure70106KPa
Heat dissipation modeNatural conduction and heat dissipation
2.2 Input characteristics
ParameterMinimalTypicalMaxUnitComment
Input voltage range90220264Vac
Input current3A
Input rush current60A220Vac input, output full load
Enter the frequency475063HzFull range normal operation
Power factor0.95220Vac input, output full load
2.3 Output characteristics
ParameterMinimalTypicalMaxUnitComment
Output voltage+4.6VVdcConfigure the output voltage from 3.3 V to 6 V according to customer requirements
Output current range040A
Ripple (peak-to-peak)200m Vp-pAt rated input/output, add and combine 0.11F ceramic chip capacitor and One each 10 10μF high frequency electrolytic capacitor with 20 MHz bandwidth Measure.
Load regulation±2%
Source adjustment rate±0.5%
2.4 Other output characteristics
ParameterMinimalTypicalMaxUnitComment
Output Power200W
Output efficiency90%220Vac input, full load output
Temperature coefficient±0.03%/℃
Startup and shutdown overshoot±10%
Dynamic Response Overshoot±5%25% -50% -25% or 50% -75% -50% load transformer
Dynamic Response Recovery Time200ūSThe load mutation rate is 0.1A/s, which is calculated by the part exceeding the output voltage stabilization accuracy range.
Power-on output delay2S
2.5 Protection characteristics
ParameterMinimalTypicalMaxUnitComment
Output overvoltage protection4.8V220Vac input, output half load test, hiccup
Output overcurrent protection45AHiccups, self-healing
Short circuit protectionHaveShort circuit for a long time and self-recovery
Over-temperature protectionHave°C
2.6 Safety regulations and insulation level
ParameterStandard requirementsComment
Input-output3000Vac/≤10mA/1min
Input-Earth1500Vac/≤10mA/1minNo flashover, no breakdown
Output-Earth500Vdc/≤10mA /1min
Grounding resistance<0.1ΩExperimental current: 32 A, experimental time: 120 S
Insulation resistance≥10MΩUnder normal atmospheric pressure, the relative humidity is 90% and the test voltage is DC 500 V, the insulation resistance of power supply input to output, input to ground and output to ground shall not be lower than 10MΩ
Leakage current≤0.7m AInput 264VAC 50HZ
2.7 EMC
ProjectIndicator requirementsStandard
Air discharge ± 8 KVIEC 61000-4-2 (Criterion A)
Electrostatic Immunity (ESD)Contact discharge ± 6 KVIEC 61000-4-2 (Criterion A)
Radiated immunity (RS)Test frequency: 80MHz ~ 2GHz Electric field intensity: 3V/m; Amplitude modulation: 80% AM (1kHz)IEC 61000-4-3 (Criterion A)
Conducted Immunity (CS)Test frequency: 0.15 MHz ~ 80 MHz, test intensity: 3 V, amplitude modulation: 80% AM (1kHz)IEC 61000-4-6 (Criterion A)
Fast Transient Burst (EFT/B)± 2kV, repetition frequency: 5KHz & 100KHz AC power port: line ± 1 kV (internal resistance 2 Ω; Line groundIEC 61000-4-4 (Criterion A)
Surge (SURGE)± 2kV (internal resistance: 12Ω)IEC 61000-4-5 (Criterion A)
Conducted disturbances (CE)CLASS B (Note 2)CISPR22 ;EN55022 ;
Radiated disturbance (RE)CLASS B (Note 2)GB9254 ;
2.8 Others
VibrationFrequency from 10Hz to 55Hz (sine sweep), amplitude 0.35 mm
ImpactPeak acceleration of 150 m/s2for 11 ms
Collision experimentCollision waveform: half sine wave; Peak acceleration: 180m/S2; Pulse width: 6ms; Collision direction: 6 directions; Number of collisions: 100 in each direction. TL=Wt×(S-1)×F×9.8(N)
Static pressure testWhere: TL: the applied pressure value, unit: N; Wt: the weight of the package itself, unit: kg; S: the number of stacking layers allowed, select the maximum number of stacking layers; F: safety factor, usually 5; The pressure is applied for 2 H.
Moisture-proofGB/T2423.4-1993 Alternate damp heat test, 24 ~ 45 ℃, 95% RH, 48h
Mildew proofMould test, grade 2
MTBF≥150,000h
Odor requirementsDo not produce peculiar smell and smell harmful to health.
2.9 Routine environmental test
ProjectIndicator requirementsStandard
Low temperature working test-25 ℃, 24h, temperature change rate 1 ℃/minGB _ T 2423.1-2008 Test Ae
High temperature working test55 ℃, 24h, temperature change rate 1 ℃/minGB _ T 2423.2-2008 Test Be
Low temperature storage test-40 ℃, 24h, temperature change rate 1 ℃/minGB _ T 2423.1-2008 Test Ab
High temperature storage test85 ℃, 24h, temperature change rate 1 ℃/minGB _ T 2423.2-2008 Test Bb
Alternating damp heat testAlternate damp heat test, temperature 25 ~ 55 ℃, Humidity 93%, 2 cycles, 48 H in total.GB_T 2423.4-2008
Temperature change test-25 to 55 deg C, 2 cycles, the high and low temperature keeping time is 3 hours respectively, Temperature change rate 1 ℃/minGB _ T 2423.22-2012 Test Nb
Bare metal crash testA half-sine pulse; Peak acceleration 20g; Pulse width 11 ms; Positive and negative directions of three axial directions; 100 times in each direction.
Bare metal drop testDrop height: 0.10 m. Part I: for all placement surfaces, each surface shall be dropped four times; Part II: All placement surfaces, one free drop per surface. -25 ℃, start 3 times. It can be started normally, drop is allowed during the starting process, and the output voltage after starting meets the requirements of the output voltage range. Enter the most
Low temperature start-up testTest at maximum, minimum and typical values
2.10 Mechanical properties
Overall dimension (L * W * H mm)165*46*26mm
Weight (kg)≤0.5Kg
Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].