Goldpower GPAD301M5-1E LED Display Switching Power Supply
$51.99
High-performance 300 W LED display power supply with 4.2 V/60 A output, wide AC input, and comprehensive protection for safe and reliable operation.
Goldpower GPAD301M5-1E LED Display Switching Power Supply Description
The Goldpower GPAD301M5-1E LED Display Switching Power Supply is a high-performance 300 W power unit designed for professional LED displays. It provides a stable 4.2 V output with up to 60 A current, supports a wide input voltage range of 90–264 V AC, and incorporates multiple protection features, including overcurrent, overvoltage, short circuit, and over-temperature protection. Its robust design ensures reliable operation even in harsh environments and meets strict EMC and safety standards.
Product Features:
• Wide Input Voltage Range: Operates reliably from 90–264V AC at 47–63Hz.
• High Output Power: 300W peak, with 4.2V output and up to 60A current.
• Comprehensive Protection: Overcurrent, overvoltage, under-voltage, short-circuit, and over-temperature protection.
• Environmental Tolerance: Supports operation from –40°C to 70°C and humidity from 20%–95% RH.
• EMC Compliance: Meets electrostatic, radiated, conducted, surge, and fast transient burst immunity standards.
• Mechanical Reliability: Tested for vibration, impact, collision, moisture, and mildew resistance.
• Efficient Operation: Output efficiency 88–90% at full load and 220V AC input.
• Natural Conduction Cooling: Ensures stable temperature performance without forced ventilation.
Goldpower GPAD301M5-1E LED Display Switching Power Supply Specification:
| 1.1 Environment | |||||
|---|---|---|---|---|---|
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Operating temperature | -40 | 70 | °C | When the temperature is above 50 degrees, it needs to be derated (see the attached table on page 4). Above -30 can be started with 70% load, and can be started after starting With full load | |
| Storage ambient temperature | -40 | 85 | °C | ||
| Operating relative humidity | 20 | 95 | % | No condensation | |
| Store relative humidity | 5 | 95 | % | No condensation | |
| Altitude | 5000 | m | |||
| Atmospheric pressure | 70 | 106 | KPa | ||
| Heat dissipation mode | Natural conduction and heat dissipation | ||||
| 1.2 Input | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Input voltage range | 90 | 220 | 264 | Vac | |
| Input current | 4 | A | |||
| Input rush current | 20 | A | 220Vac input, output full load | ||
| Enter the frequency | 47 | 50 | 63 | Hz | Full range normal operation |
| Power factor | 0.95 | 220Vac input, output full load | |||
| 1.3 Basic output characteristics | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output voltage | 4.2 | Vdc | |||
| Output voltage range | 4.1 | 4.2 | 4.6 | Vdc | |
| Output current range | 0 | 60 | A | ||
| Ripple (peak-to-peak) | 200 | m Vp-p | At rated input/output, add a 0.11μF ceramic capacitor and a 1010μF high frequency electrolytic capacitor respectively, and the bandwidth is 20MHz for measurement. The ripple is less than 300 m when the temperature is below minus 20 Vp-p | ||
| Load regulation | ±5 | % | |||
| Voltage stabilization accuracy | ±2 | % | |||
| Source adjustment rate | ±2 | % | |||
| 1.4 Other output characteristics | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output Power | 300 | W | 300 W peak | ||
| Output efficiency | 88 | 90 | % | 220Vac input, full load output | |
| Temperature coefficient | ±0.03 | %/℃ | |||
| Startup and shutdown overshoot | ±10 | % | |||
| Dynamic Response Overshoot | ±5 | % | 25% -50% -25% or 50% -75% -50% load transformer | ||
| Dynamic Response Recovery Time | 200 | ūS | The load mutation rate is 0.1A/s, which is calculated by the part exceeding the output voltage stabilization accuracy range. | ||
| Power-on output delay | 4 | S | |||
| 1.5 Protection | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Input overvoltage protection | 265 | 300 | V | Output half load test | |
| Input overvoltage recovery | 260 | 295 | V | Output half load test | |
| Input undervoltage protection | 68 | 88 | V | Output half load test | |
| Input undervoltage recovery | 70 | 90 | V | Output half load test | |
| Output overvoltage protection | 5.1 | 5.6 | V | 220Vac input, output half-load test | |
| Output overcurrent protection | 66 | 96 | A | Hiccups, self-healing | |
| Short circuit protection | Have | Short circuit for a long time and self-recovery | |||
| Over-temperature protection | Have | °C | Shutdown output after overtemperature, self-recovery | ||
| 1.6 EMC | |||||
| Project | Indicator requirements | Standard | |||
| Electrostatic Immunity (ESD) | Air discharge ± 8 KV | IEC 61000-4-2 (Criterion A) | |||
| Contact discharge ± 6 KV | IEC 61000-4-2 (Criterion A) | ||||
| Radiated immunity (RS) | Test frequency: 80MHz ~ 2GHz Electric field intensity: 3V/m;Amplitude modulation: 80% AM (1kHz) | IEC 61000-4-3 (Criterion A) | |||
| Conducted Immunity (CS) | Test frequency: 0.15 MHz ~ 80 MHz, test intensity: 3 V, amplitude modulation: 80% AM (1kHz) | IEC 61000-4-6 (Criterion A) | |||
| Fast Transient Burst (EFT/B) | ± 2kV, repetition frequency: 5KHz & 100KHz | IEC 61000-4-4 (Criterion A) | |||
| Surge (SURGE) | AC power port: Line ± 1 kV (internal resistance 2 Ω) Line ground ± 2 kV (internal resistance 12 Ω) | IEC 61000-4-5 (Criterion A) | |||
| Conducted disturbances (CE) | CLASS B (Note 2) | CISPR22 ;EN55022 ;GB9254 ; | |||
| 1.7 Others | |||||
| Vibration | Frequency from 10Hz to 55Hz (sine sweep), amplitude 0.35 mm | ||||
| Impact | Peak acceleration of 150 m/s2for 11 ms | ||||
| Collision experiment | Collision waveform: half sine wave; Peak acceleration: 180m/S2; Pulse width: 6ms; Collision direction: 6 directions; Collision times | ||||
| Number: 100 times in each direction. | |||||
| Static pressure test | TL=Wt×(S-1)×F×9.8(N) Where: TL: the applied pressure value, in N; Wt: the weight of the package itself, in kg; S: Layers allowed for stacking Number, select the maximum number of stacking layers; F: safety factor, usually 5; The pressure is applied for 2 H. | ||||
| Moisture-proof | GB/T2423.4-1993 Alternate damp heat test, 24 ~ 45 ℃, 95% RH, 48h | ||||
| Mildew proof | Mould test, grade 2 | ||||
| MFBF | MTBF≥200,000h | ||||
| Odor requirements | Do not produce peculiar smell and smell harmful to health. | ||||
| 1.8 Safety regulations and insulation level | |||||
| Parameter | Standard requirements | Comment | |||
| Input-output | 3000Vac/≤10mA/1min | No flashover, no breakdown | |||
| Input-Earth | 1500Vac/≤10mA/1min | No flashover, no breakdown | |||
| Output-Earth | 500Vdc/≤10mA /1min | No flashover, no breakdown | |||
| Grounding resistance | <0.1Ω | ||||
| Insulation resistance | ≥20MΩ | Under normal atmospheric pressure, the relative humidity is 90% and the test voltage is DC 500 V, the insulation resistance of power supply input to output, input to ground and output to ground shall not be less than20MΩ | |||
| 1.9 Mechanical properties | |||||
| Dimensions (L * W * H) | 220*50*30mm | ||||
| Weight (kg) | ≤0.6Kg | ||||
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].































































Reviews
There are no reviews yet.