Goldpower TYAD201M4.6-1A LED Display Switching Power Supply

$49.99

The TYAD201M4.6-1A is a customized power supply developed and manufactured by Goldpower with an AC input voltage range of 200 ~ 240Vac. It has a single output and features output short circuit protection, overcurrent protection, and output overvoltage protection. Designed in strict accordance with safety requirements, it meets the safety standards of information technology equipment.

Weight 1 kg
Dimensions 20.8 × 5.9 × 3.1 mm
GOLDPOWER
Description

Goldpower TYAD201M4.6-1A LED Display Switching Power Supply Description

The Goldpower TYAD201M4.6-1A is a high-quality customized power supply designed and manufactured by Goldpower. With an input voltage range of 200-240Vac, this power supply is suitable for normal operation. The power supply features a single output and comes equipped with output short circuit protection, overcurrent protection, output overvoltage protection, and more. It is designed in strict accordance with safety requirements and meets the safety standards for information technology equipment.
The power supply has a load regulation of ±3%, voltage stabilization accuracy of ±2%, and source adjustment rate of ±2%. Noise and ripple (peak-to-peak) are limited to 200mV with a rated 220Vac input and full load output test. The output voltage range is 4.5Vdc, with an output current range of 0-40A. The power supply has an output power of 200W, and an output efficiency of 87% at 220Vac input and output full load.

The TYAD201M4.6-1A is equipped with various protection mechanisms, including output current limiting protection, output short circuit protection, and output overvoltage protection. In addition, it meets several EMC standards, including electrostatic discharge, radiated immunity, conducted immunity, surge, and fast transient burst.

This power supply has undergone several environmental tests, including low and high-temperature working tests, low and high-temperature storage tests, alternating damp heat tests, temperature change tests, bare metal crash tests, bare metal drop tests, and low-temperature start-up tests. It meets safety regulations and insulation levels, including input-output, input-earth, output-earth, insulation resistance, and contact current.

1.1 Environment
ParameterMinimalTypicalMaxUnitComment
Operating temperature-2555°CNormal operation of 200Vac ~ 240Vac
Storage temperature-25100°C
Relative humidity595%No condensation
Heat dissipation modeThe bottom plate is close to the radiator
1.2 Input
ParameterMinimalTypicalMaxUnitComment
AC input voltage range200240Vac
AC input voltage frequency4750/6063Hz
Input rush current60A220Vac full load/cold test
1.3 Basic output characteristics
ParameterMinimalTypicalMaxUnitComment
Output voltage range4.5Vdc
Output current range040A
Load regulation±3%Rated voltage input, full load variation
Voltage stabilization accuracy±2%Full voltage input range/full load output
Source adjustment rate±2%Rated current output, full voltage range variation
Noise + Ripple (peak-to-peak)200mVRated 220Vac input, full load output test. During the test, a 0.1 uF ceramic capacitor or a gold film capacitor and a 10uF electrolytic capacitor are added at the output end, and the bandwidth of the oscilloscope is 20MHz
1.4 Other output characteristics
ParameterMinimalTypicalMaxUnitComment
Output Power200W
Output efficiency87%220Vac input, output full load
Temperature coefficient±0.02%/Rated output voltage and output current, full operating temperature range
Power-on output delay4S220Vac input, output full load
Output Voltage Rise Time100msRated input/rated output
1.5 Protection
ParameterMinimalTypicalMaxUnitComment
Output current limiting protection point4565AHiccup mode, self-healing. Input 220Vac test
Output short circuit protectionHiccup mode, can be short circuit for a long time, after the short circuit is eliminated, it can be automatically Resume
Output overvoltage protection4.85.5VFull load test at room temperature, hiccup mode
1.6 EMC and others
ParameterStandard requirements
Electrostatic discharge (ESD)EN61000-4-2 Contact discharge: ± 4 KV, air discharge: ± 8 KV. (Criterion B)
Radiated immunity (RS)EN61000-4-3 LEVEL 3; Criteria A; 10V/m field strength
Conducted Immunity (CS)EN61000-4-6 (the output end of the power module shall also be tested) LEVEL 3; Criterion A: 10V
Surge (SURGE)EN61000-4-5 Input: line-to-line 1 KV, line-to-ground 2 KV
Fast Transient Burst EFT/B± 2KV, LEVEL 3, Criterion B IEC61000-4-4
Vibration1. Frequency range: 5Hz ~ 200Hz ~ 5Hz;
2. 5Hz ~ 9Hz: amplitude 6.1mm (0-P);
3. 9Hz ~ 200Hz: acceleration 2g;
4. The sweep rate shall not be greater than 1 octave per minute;
5. The test direction is three mutually perpendicular axis directions of the test sample, with 5 cycles in each direction;
ImpactImpulse waveform: half sine wave; Peak acceleration: 300m/S2; Pulse width: 6ms; Axial direction of impact: 6 directions; Number of impacts: 3 in each direction
Voltage fluctuation and flickerPst1.0 dc3% P1t0.65 dmax4% D (t) value exceeds 3.3%200ms
Acoustic noise50dB(A); Test distance 1m
MTBFMTBF100,000h
Odor requirementsDo not produce peculiar smell and smell harmful to health.
1.7 Routine environmental test
ProjectStandardIndicator requirements
Low temperature working testGB _ T 2423.1-2008 Test Ae-25 , 24h, temperature change rate 1 /min
High temperature working testGB _ T 2423.2-2008 Test Be55 , 24h, temperature change rate 1 /min
Low temperature storage testGB _ T 2423.1-2008 Test Ab-25 , 24h, temperature change rate 1 /min
High temperature storage testGB _ T 2423.2-2008 Test Bb100 , 24h, temperature change rate 1 /min
Alternating damp heat testGB_T 2423.4-2008Alternate damp heat test at -25 to 55 deg C,Humidity 93%, 2 cycles, 48 H in total.
Temperature change testGB _ T 2423.22-2012 Test Nb-25 ~ 55 , 2 cycles, the holding time of high and low temperature is 3 hours respectively, and the temperature change rate is 1 /min
Bare metal crash testA half-sine pulse; Peak acceleration 20g; Pulse width 11 ms; Positive and negative directions of three axial directions; 100 times in each direction.
Bare metal drop testDrop height: 0.10 m. Part I: for all placement surfaces, each surface shall be dropped four times; Part II: All placement surfaces, one free drop per surface.
Low temperature start-up test-25 , start 3 times. It can be started normally, drop is allowed during the starting process, and the output voltage after starting meets the requirements of the output voltage range. Enter the mostTest at maximum, minimum and typical values
1.8 Safety regulations and insulation level
ParameterStandard requirementsComment
Input-output3000Vac/10mA//1minNo flashover, no breakdown
Input-Earth1500Vac/10mA//1minNo flashover, no breakdown
Output-Earth500Vdc/10mA//1minNo flashover, no breakdown
Insulation resistance≥10MΩUnder normal atmospheric pressure, relative humidity < 90%, test voltage 500 Vdc, power input vs. output, inputInsulation resistance to ground and output to ground 10 MΩ
Contact current1mATest L and N respectively
1.9 Mechanical properties
L * W * H (mm)208*59*31mm
Weight (kg)1
Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].