GPAD201M4.2-1E Customized Power Supply | Single Output Power Supply
The GPAD201M4.2-1E customized power supply is designed with strict adherence to safety standards for information technology equipment. It has a wide input voltage range of 90 ~ 264Vac and provides single output power supply with output short circuit protection, overcurrent protection, and output overvoltage protection.
$39.99
GPAD201M4.2-1E Customized Power Supply | Single Output Power Supply Description
The GPAD201M4.2-1E customized power supply is a high-quality power source designed for a wide range of applications. With a wide input voltage range of 90~264Vac, it can operate under a wide range of conditions. The power supply has a single output and offers output short circuit protection, overcurrent protection, and output overvoltage protection.
Designed with safety in mind, the GPAD201M4.2-1E power supply meets the safety standards for information technology equipment, ensuring the safety of the user and the equipment being powered. The power supply has a maximum output power of 200W and a high efficiency of 85%, making it a reliable power source for demanding applications.
In terms of basic output characteristics, the GPAD201M4.2-1E power supply has an output voltage range of 4.2Vdc and an output current range of 0~40A. It has a load regulation of ±3% and voltage stabilization accuracy of ±5%. The source adjustment rate is ±2% and it has a noise + ripple (peak-to-peak) of 200mV.
The power supply also offers protection features such as output overvoltage protection and output current limiting protection point. It has passed various EMC tests and meets the safety regulations and insulation level requirements.
In summary, the GPAD201M4.2-1E customized power supply is a reliable power source that provides a wide input voltage range, single output, and various protection features. It meets strict safety standards and has passed various EMC tests. With its high efficiency and excellent performance, it is suitable for various demanding applications.
Key Features:
- Wide input voltage range of 90~264Vac
- Single output with output short circuit, overcurrent, and overvoltage protection
- Safety standards compliant for information technology equipment
- Maximum output power of 200W and high efficiency of 85%
- Load regulation of ±3% and voltage stabilization accuracy of ±5%
- Passed various EMC tests and meets safety regulations and insulation level requirements
1.1 Environment | |||||
---|---|---|---|---|---|
Parameter | Minimal | Typical | Max | Unit | Comment |
Operating temperature | -25 | 55 | °C | ||
Storage temperature | -25 | 100 | °C | ||
Relative humidity | 5 | 95 | % | No condensation | |
Altitude | 0 | 4000 | m | The high temperature derating under the service condition of 3000 ~ 4000 m shall be reduced by 1 ℃ for every 200 m. | |
Heat dissipation mode | The bottom plate is close to the radiator | ||||
1.2 Input | |||||
Parameter | Minimal | Typical | Max | Unit | Comment |
AC input voltage range | 90 | 110/220 | 264 | Vac | |
AC input voltage frequency | 47 | 50/60 | 63 | Hz | |
Power factor | 0.9 | 220Vac full load | |||
Input rush current | 50 | A | 220Vac full load/cold test | ||
1.3 Basic output characteristics | |||||
Parameter | Minimal | Typical | Max | Unit | Comment |
Output voltage range | 4.2 | Vdc | |||
Output current range | 0 | 40 | A | Long-term operation of load 30 A, instantaneous peak current 40 A | |
Load regulation | ±3 | % | Rated voltage input, full load variation | ||
Voltage stabilization accuracy | ±5 | % | Full voltage input range/full load output | ||
Source adjustment rate | ±2 | % | Rated current output, full voltage range variation | ||
Noise + Ripple (peak-to-peak) | 200 | mV | 220Vac input voltage and full load 30 A are tested, and a 0.1 uF ceramic capacitor or a gold film capacitor and a 10uF electrolytic capacitor are added at the output end during the test. The bandwidth of the oscilloscope is 20 MHz. | ||
1.4 Other output characteristics | |||||
Parameter | Minimal | Typical | Max | Unit | Comment |
Output Power | 200 | W | |||
Output efficiency | 85 | % | 220Vac input, output full load | ||
Temperature coefficient | ±0.02 | %/℃ | Rated output voltage and output current, full operating temperature range | ||
Power-on output delay | 4 | S | Full load test at 220Vac | ||
Output Voltage Rise Time | 50 | ms | Rated input/rated output | ||
1.5 Protection | |||||
Parameter | Minimal | Typical | Max | Unit | Comment |
Output overvoltage protection point | 5 | 5.5 | V | ||
Output current limiting protection point | 44 | 60 | A | Full load test at 220Vac, self-recovery | |
Output short circuit protection | Long-term short circuit and self-recovery | ||||
1.6 EMC and others | |||||
Parameter | Standard requirements | ||||
Radiated Emission (CE) | CLASS A Standard GB9254-2008 (IDT CISPR 22:2006) | ||||
Conducted interference (RE) | CLASS A Standard GB9254-2008 (IDT CISPR 22:2006) | ||||
Electrostatic discharge (ESD) | EN61000-4-2 ± 4 KV contact discharge, ± 8 KV air discharge. (Criterion B) | ||||
Radiated immunity (RS) | EN61000-4-3 LEVEL 3; Criteria A; 10V/m field strength | ||||
Conducted Immunity (CS) | EN61000-4-6 (the output end of the power module shall also be tested) LEVEL 3; Criterion A: 10V | ||||
Surge (SURGE) | EN61000-4-5 Input: line-to-line 1 KV, line-to-ground 2 KV | ||||
Fast Transient Burst (EFT/B) | ± 2KV, LEVEL 3, criterion B IEC61000-4-4 | ||||
Vibration | Frequency 1-4Hz, acceleration spectral density 0.0001 G2/Hz; Frequency 4-100Hz, acceleration spectral density 0.01 G2/Hz; Frequency 100-200Hz, acceleration spectral density 0.001 G2/Hz; Total RMS acceleration: 0.781 Grms; Test axial direction: 3 axial directions. Test time: 30 min in each axial direction. | ||||
Impact | Impulse waveform: half sine wave; Peak acceleration: 300m/S2; Pulse width: 6ms; Axial direction of impact: 6 directions; Number of impacts: 3 in each direction | ||||
Voltage fluctuation and flicker | Pst≤1.0 dc≤3% | ||||
P1t ≤ 0.65 dmax ≤ 4% d (t) value exceeds 3.3% ≤ 200ms | |||||
Current harmonic emission | CLASS A IEC61000-3-2 {6} | ||||
Acoustic noise | 55dB(A); Test distance 1m | ||||
MTBF | MTBF≥100,000h | ||||
Odor requirements | Do not produce peculiar smell and smell harmful to health. | ||||
1.7 Safety regulations and insulation level | |||||
Parameter | Standard requirements | Comment | |||
Input-output | 3000Vac/10mA//1min | No flashover, no breakdown | |||
Input-Earth | 1500Vac/10mA//1min | No flashover, no breakdown | |||
Output-Earth | 500Vdc/10mA//1min | No flashover, no breakdown | |||
Insulation resistance | ≥10MΩ | Under normal atmospheric pressure, relative humidity < 90%, when the test voltage is 500Vdc, the power supply input to output, input to ground, output to ground insulation resistance ≥ 10 MΩ | |||
1.8 Mechanical properties | |||||
Dimension (mm) | As shown in the figure below | ||||
Weight (kg) | <0.5Kg |