GPAD201M4.2-1E Customized Power Supply | Single Output Power Supply

$49.99

The GPAD201M4.2-1E customized power supply is designed with strict adherence to safety standards for information technology equipment. It has a wide input voltage range of 90 ~ 264Vac and provides single output power supply with output short circuit protection, overcurrent protection, and output overvoltage protection.

SKU: GPAD201M421E Categories: ,
GOLDPOWER
Description

GPAD201M4.2-1E Customized Power Supply | Single Output Power Supply Description

The GPAD201M4.2-1E customized power supply is a high-quality power source designed for a wide range of applications. With a wide input voltage range of 90~264Vac, it can operate under a wide range of conditions. The power supply has a single output and offers output short circuit protection, overcurrent protection, and output overvoltage protection.

Designed with safety in mind, the GPAD201M4.2-1E power supply meets the safety standards for information technology equipment, ensuring the safety of the user and the equipment being powered. The power supply has a maximum output power of 200W and a high efficiency of 85%, making it a reliable power source for demanding applications.

In terms of basic output characteristics, the GPAD201M4.2-1E power supply has an output voltage range of 4.2Vdc and an output current range of 0~40A. It has a load regulation of ±3% and voltage stabilization accuracy of ±5%. The source adjustment rate is ±2% and it has a noise + ripple (peak-to-peak) of 200mV.

The power supply also offers protection features such as output overvoltage protection and output current limiting protection point. It has passed various EMC tests and meets the safety regulations and insulation level requirements.

In summary, the GPAD201M4.2-1E customized power supply is a reliable power source that provides a wide input voltage range, single output, and various protection features. It meets strict safety standards and has passed various EMC tests. With its high efficiency and excellent performance, it is suitable for various demanding applications.

Key Features:

  • Wide input voltage range of 90~264Vac
  • Single output with output short circuit, overcurrent, and overvoltage protection
  • Safety standards compliant for information technology equipment
  • Maximum output power of 200W and high efficiency of 85%
  • Load regulation of ±3% and voltage stabilization accuracy of ±5%
  • Passed various EMC tests and meets safety regulations and insulation level requirements
    1.1 Environment
    ParameterMinimalTypicalMaxUnitComment
    Operating temperature-2555°C
    Storage temperature-25100°C
    Relative humidity595%No condensation
    Altitude04000mThe high temperature derating under the service condition of 3000 ~ 4000 m shall be reduced by 1 for every 200 m.
    Heat dissipation modeThe bottom plate is close to the radiator
    1.2 Input
    ParameterMinimalTypicalMaxUnitComment
    AC input voltage range90110/220264Vac
    AC input voltage frequency4750/6063Hz
    Power factor0.9220Vac full load
    Input rush current50A220Vac full load/cold test
    1.3 Basic output characteristics
    ParameterMinimalTypicalMaxUnitComment
    Output voltage range4.2Vdc
    Output current range040ALong-term operation of load 30 A, instantaneous peak current 40 A
    Load regulation±3%Rated voltage input, full load variation
    Voltage stabilization accuracy±5%Full voltage input range/full load output
    Source adjustment rate±2%Rated current output, full voltage range variation
    Noise + Ripple (peak-to-peak)200mV220Vac input voltage and full load 30 A are tested, and a 0.1 uF ceramic capacitor or a gold film capacitor and a 10uF electrolytic capacitor are added at the output end during the test. The bandwidth of the oscilloscope is 20 MHz.
    1.4 Other output characteristics
    ParameterMinimalTypicalMaxUnitComment
    Output Power200W
    Output efficiency85%220Vac input, output full load
    Temperature coefficient±0.02%/Rated output voltage and output current, full operating temperature range
    Power-on output delay4SFull load test at 220Vac
    Output Voltage Rise Time50msRated input/rated output
    1.5 Protection
    ParameterMinimalTypicalMaxUnitComment
    Output overvoltage protection point55.5V
    Output current limiting protection point4460AFull load test at 220Vac, self-recovery
    Output short circuit protectionLong-term short circuit and self-recovery
    1.6 EMC and others
    ParameterStandard requirements
    Radiated Emission (CE)CLASS A Standard GB9254-2008 (IDT CISPR 22:2006)
    Conducted interference (RE)CLASS A Standard GB9254-2008 (IDT CISPR 22:2006)
    Electrostatic discharge (ESD)EN61000-4-2 ± 4 KV contact discharge, ± 8 KV air discharge. (Criterion B)
    Radiated immunity (RS)EN61000-4-3 LEVEL 3; Criteria A; 10V/m field strength
    Conducted Immunity (CS)EN61000-4-6 (the output end of the power module shall also be tested) LEVEL 3; Criterion A: 10V
    Surge (SURGE)EN61000-4-5 Input: line-to-line 1 KV, line-to-ground 2 KV
    Fast Transient Burst (EFT/B)± 2KV, LEVEL 3, criterion B IEC61000-4-4
    VibrationFrequency 1-4Hz, acceleration spectral density 0.0001 G2/Hz; Frequency 4-100Hz, acceleration spectral density 0.01 G2/Hz; Frequency 100-200Hz, acceleration spectral density 0.001 G2/Hz; Total RMS acceleration: 0.781 Grms; Test axial direction: 3 axial directions. Test time: 30 min in each axial direction.
    ImpactImpulse waveform: half sine wave; Peak acceleration: 300m/S2; Pulse width: 6ms; Axial direction of impact: 6 directions; Number of impacts: 3 in each direction
    Voltage fluctuation and flickerPst1.0 dc3%
    P1t 0.65 dmax 4% d (t) value exceeds 3.3% 200ms
    Current harmonic emissionCLASS A IEC61000-3-2 {6}
    Acoustic noise55dB(A); Test distance 1m
    MTBFMTBF100,000h
    Odor requirementsDo not produce peculiar smell and smell harmful to health.
    1.7 Safety regulations and insulation level
    ParameterStandard requirementsComment
    Input-output3000Vac/10mA//1minNo flashover, no breakdown
    Input-Earth1500Vac/10mA//1minNo flashover, no breakdown
    Output-Earth500Vdc/10mA//1minNo flashover, no breakdown
    Insulation resistance10MΩUnder normal atmospheric pressure, relative humidity < 90%, when the test voltage is 500Vdc, the power supply input to output, input to ground, output to ground insulation resistance 10 MΩ
    1.8 Mechanical properties
    Dimension (mm)As shown in the figure below
    Weight (kg)0.5Kg
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GPAD201M4.2-1E Customized Power Supply | Single Output Power Supply”

Your email address will not be published. Required fields are marked *

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].