Goldpower GPAD201M4.2-1E Customized Power Supply

$59.99

The Goldpower GPAD201M4.2-1E customized power supply is designed with strict adherence to safety standards for information technology equipment. It has a wide input voltage range of 90 ~ 264Vac and provides single output power supply with output short circuit protection, overcurrent protection, and output overvoltage protection.

SKU: GPAD201M421E Categories: ,
GOLDPOWER
Description

GPAD201M4.2-1E Customized Power Supply Description

Goldpower GPAD201M4.2-1E is a single-output customized power supply designed for demanding applications requiring a stable low-voltage rail. It supports 90–264VAC, 47–63Hz input with PF≈0.9 (220VAC, full load), and provides a regulated 4.2V DC output up to 40A (recommended 30A continuous), with ≤200W rated power and 85% efficiency. Built-in protections include output short-circuit, overcurrent/current-limit (self-recovery), and over-voltage protection. The unit meets IT equipment safety requirements and passes EMC tests (CISPR/EN Class A). Operating range is −25 to +55°C, 5–95% RH (non-condensing), altitude to 4000m (apply derating above 3000m). Baseplate cooling for installation against a heatsink/radiator shortens thermal paths and enhances reliability.

Product Features:
• Wide AC input: 90–264VAC, 47–63Hz; inrush ≤50A at 220VAC (cold start)
• Single 4.2V DC output, 0–40A; recommended 30A long-term, 40A peak
• Output performance: load regulation ±3%, line regulation ±2%, voltage accuracy ±5%, ripple/noise ≤200mVp-p (20MHz BW, standard test caps)
• Efficiency: 85% at 220VAC, full load; power-on delay ≤4s; rise time ≤50ms
• Protections: output OVP (5.0–5.5V), current-limit 44–60A (auto-recover), short-circuit (long-term, auto-recover)
• Environment: −25 to +55°C operating, −25 to +100°C storage, 5–95% RH; acoustic noise ≤55dB(A) @1m
• Safety/insulation: I/P–O/P 3000VAC/1min; I/P–Earth 1500VAC/1min; O/P–Earth 500VDC/1min; insulation ≥10MΩ @500VDC
• EMC: CE/RE Class A; ESD ±4kV contact/±8kV air; RS 10V/m; EFT ±2kV; Surge L-L 1kV, L-PE 2kV; CS 10V; harmonics Class A; flicker compliant
• Reliability: MTBF ≥100,000h; vibration/impact tested; odor-free requirement
• Mechanical: approx. 0.5kg; baseplate-to-heatsink mounting for conduction cooling

GPAD201M4.2-1E Customized Power Supply Specification:

Edit
1.1 Environment
Parameter Minimal Typical Max Unit Comment
Operating temperature -25 55 °C
Storage temperature -25 100 °C
Relative humidity 5 95 % No condensation
Altitude 0 4000 m The high temperature derating under the service condition of 3000 ~ 4000 m shall be reduced by 1 ℃ for every 200 m.
Heat dissipation mode The bottom plate is close to the radiator
1.2 Input
Parameter Minimal Typical Max Unit Comment
AC input voltage range 90 110/220 264 Vac
AC input voltage frequency 47 50/60 63 Hz
Power factor 0.9 220Vac full load
Input rush current 50 A 220Vac full load/cold test
1.3 Basic output characteristics
Parameter Minimal Typical Max Unit Comment
Output voltage range 4.2 Vdc
Output current range 0 40 A Long-term operation of load 30 A, instantaneous peak current 40 A
Load regulation ±3 % Rated voltage input, full load variation
Voltage stabilization accuracy ±5 % Full voltage input range/full load output
Source adjustment rate ±2 % Rated current output, full voltage range variation
Noise + Ripple (peak-to-peak) 200 mV 220Vac input voltage and full load 30 A are tested, and a 0.1 uF ceramic capacitor or a gold film capacitor and a 10uF electrolytic capacitor are added at the output end during the test. The bandwidth of the oscilloscope is 20 MHz.
1.4 Other output characteristics
Parameter Minimal Typical Max Unit Comment
Output Power 200 W
Output efficiency 85 % 220Vac input, output full load
Temperature coefficient ±0.02 %/℃ Rated output voltage and output current, full operating temperature range
Power-on output delay 4 S Full load test at 220Vac
Output Voltage Rise Time 50 ms Rated input/rated output
1.5 Protection
Parameter Minimal Typical Max Unit Comment
Output overvoltage protection point 5 5.5 V
Output current limiting protection point 44 60 A Full load test at 220Vac, self-recovery
Output short circuit protection Long-term short circuit and self-recovery
1.6 EMC and others
Parameter Standard requirements
Radiated Emission (CE) CLASS A Standard GB9254-2008 (IDT CISPR 22:2006)
Conducted interference (RE) CLASS A Standard GB9254-2008 (IDT CISPR 22:2006)
Electrostatic discharge (ESD) EN61000-4-2 ± 4 KV contact discharge, ± 8 KV air discharge. (Criterion B)
Radiated immunity (RS) EN61000-4-3 LEVEL 3; Criteria A; 10V/m field strength
Conducted Immunity (CS) EN61000-4-6 (the output end of the power module shall also be tested) LEVEL 3; Criterion A: 10V
Surge (SURGE) EN61000-4-5 Input: line-to-line 1 KV, line-to-ground 2 KV
Fast Transient Burst (EFT/B) ± 2KV, LEVEL 3, criterion B IEC61000-4-4
Vibration Frequency 1-4Hz, acceleration spectral density 0.0001 G2/Hz; Frequency 4-100Hz, acceleration spectral density 0.01 G2/Hz; Frequency 100-200Hz, acceleration spectral density 0.001 G2/Hz; Total RMS acceleration: 0.781 Grms; Test axial direction: 3 axial directions. Test time: 30 min in each axial direction.
Impact Impulse waveform: half sine wave; Peak acceleration: 300m/S2; Pulse width: 6ms; Axial direction of impact: 6 directions; Number of impacts: 3 in each direction
Voltage fluctuation and flicker Pst≤1.0 dc≤3%
P1t ≤ 0.65 dmax ≤ 4% d (t) value exceeds 3.3% ≤ 200ms
Current harmonic emission CLASS A IEC61000-3-2 {6}
Acoustic noise 55dB(A); Test distance 1m
MTBF MTBF≥100,000h
Odor requirements Do not produce peculiar smell and smell harmful to health.
1.7 Safety regulations and insulation level
Parameter Standard requirements Comment
Input-output 3000Vac/10mA//1min No flashover, no breakdown
Input-Earth 1500Vac/10mA//1min No flashover, no breakdown
Output-Earth 500Vdc/10mA//1min No flashover, no breakdown
Insulation resistance ≥10MΩ Under normal atmospheric pressure, relative humidity < 90%, when the test voltage is 500Vdc, the power supply input to output, input to ground, output to ground insulation resistance ≥ 10 MΩ
1.8 Mechanical properties
Dimension (mm) As shown in the figure below
Weight (kg) <0.5Kg
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Goldpower GPAD201M4.2-1E Customized Power Supply”

Your email address will not be published. Required fields are marked *

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].