Goldpower GPAD201M4.2-1E Customized Power Supply
$59.99
The Goldpower GPAD201M4.2-1E customized power supply is designed with strict adherence to safety standards for information technology equipment. It has a wide input voltage range of 90 ~ 264Vac and provides single output power supply with output short circuit protection, overcurrent protection, and output overvoltage protection.
GPAD201M4.2-1E Customized Power Supply Description
Goldpower GPAD201M4.2-1E is a single-output customized power supply designed for demanding applications requiring a stable low-voltage rail. It supports 90–264VAC, 47–63Hz input with PF≈0.9 (220VAC, full load), and provides a regulated 4.2V DC output up to 40A (recommended 30A continuous), with ≤200W rated power and 85% efficiency. Built-in protections include output short-circuit, overcurrent/current-limit (self-recovery), and over-voltage protection. The unit meets IT equipment safety requirements and passes EMC tests (CISPR/EN Class A). Operating range is −25 to +55°C, 5–95% RH (non-condensing), altitude to 4000m (apply derating above 3000m). Baseplate cooling for installation against a heatsink/radiator shortens thermal paths and enhances reliability.
Product Features:
• Wide AC input: 90–264VAC, 47–63Hz; inrush ≤50A at 220VAC (cold start)
• Single 4.2V DC output, 0–40A; recommended 30A long-term, 40A peak
• Output performance: load regulation ±3%, line regulation ±2%, voltage accuracy ±5%, ripple/noise ≤200mVp-p (20MHz BW, standard test caps)
• Efficiency: 85% at 220VAC, full load; power-on delay ≤4s; rise time ≤50ms
• Protections: output OVP (5.0–5.5V), current-limit 44–60A (auto-recover), short-circuit (long-term, auto-recover)
• Environment: −25 to +55°C operating, −25 to +100°C storage, 5–95% RH; acoustic noise ≤55dB(A) @1m
• Safety/insulation: I/P–O/P 3000VAC/1min; I/P–Earth 1500VAC/1min; O/P–Earth 500VDC/1min; insulation ≥10MΩ @500VDC
• EMC: CE/RE Class A; ESD ±4kV contact/±8kV air; RS 10V/m; EFT ±2kV; Surge L-L 1kV, L-PE 2kV; CS 10V; harmonics Class A; flicker compliant
• Reliability: MTBF ≥100,000h; vibration/impact tested; odor-free requirement
• Mechanical: approx. 0.5kg; baseplate-to-heatsink mounting for conduction cooling
GPAD201M4.2-1E Customized Power Supply Specification:
| 1.1 Environment | |||||
|---|---|---|---|---|---|
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Operating temperature | -25 | 55 | °C | ||
| Storage temperature | -25 | 100 | °C | ||
| Relative humidity | 5 | 95 | % | No condensation | |
| Altitude | 0 | 4000 | m | The high temperature derating under the service condition of 3000 ~ 4000 m shall be reduced by 1 ℃ for every 200 m. | |
| Heat dissipation mode | The bottom plate is close to the radiator | ||||
| 1.2 Input | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| AC input voltage range | 90 | 110/220 | 264 | Vac | |
| AC input voltage frequency | 47 | 50/60 | 63 | Hz | |
| Power factor | 0.9 | 220Vac full load | |||
| Input rush current | 50 | A | 220Vac full load/cold test | ||
| 1.3 Basic output characteristics | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output voltage range | 4.2 | Vdc | |||
| Output current range | 0 | 40 | A | Long-term operation of load 30 A, instantaneous peak current 40 A | |
| Load regulation | ±3 | % | Rated voltage input, full load variation | ||
| Voltage stabilization accuracy | ±5 | % | Full voltage input range/full load output | ||
| Source adjustment rate | ±2 | % | Rated current output, full voltage range variation | ||
| Noise + Ripple (peak-to-peak) | 200 | mV | 220Vac input voltage and full load 30 A are tested, and a 0.1 uF ceramic capacitor or a gold film capacitor and a 10uF electrolytic capacitor are added at the output end during the test. The bandwidth of the oscilloscope is 20 MHz. | ||
| 1.4 Other output characteristics | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output Power | 200 | W | |||
| Output efficiency | 85 | % | 220Vac input, output full load | ||
| Temperature coefficient | ±0.02 | %/℃ | Rated output voltage and output current, full operating temperature range | ||
| Power-on output delay | 4 | S | Full load test at 220Vac | ||
| Output Voltage Rise Time | 50 | ms | Rated input/rated output | ||
| 1.5 Protection | |||||
| Parameter | Minimal | Typical | Max | Unit | Comment |
| Output overvoltage protection point | 5 | 5.5 | V | ||
| Output current limiting protection point | 44 | 60 | A | Full load test at 220Vac, self-recovery | |
| Output short circuit protection | Long-term short circuit and self-recovery | ||||
| 1.6 EMC and others | |||||
| Parameter | Standard requirements | ||||
| Radiated Emission (CE) | CLASS A Standard GB9254-2008 (IDT CISPR 22:2006) | ||||
| Conducted interference (RE) | CLASS A Standard GB9254-2008 (IDT CISPR 22:2006) | ||||
| Electrostatic discharge (ESD) | EN61000-4-2 ± 4 KV contact discharge, ± 8 KV air discharge. (Criterion B) | ||||
| Radiated immunity (RS) | EN61000-4-3 LEVEL 3; Criteria A; 10V/m field strength | ||||
| Conducted Immunity (CS) | EN61000-4-6 (the output end of the power module shall also be tested) LEVEL 3; Criterion A: 10V | ||||
| Surge (SURGE) | EN61000-4-5 Input: line-to-line 1 KV, line-to-ground 2 KV | ||||
| Fast Transient Burst (EFT/B) | ± 2KV, LEVEL 3, criterion B IEC61000-4-4 | ||||
| Vibration | Frequency 1-4Hz, acceleration spectral density 0.0001 G2/Hz; Frequency 4-100Hz, acceleration spectral density 0.01 G2/Hz; Frequency 100-200Hz, acceleration spectral density 0.001 G2/Hz; Total RMS acceleration: 0.781 Grms; Test axial direction: 3 axial directions. Test time: 30 min in each axial direction. | ||||
| Impact | Impulse waveform: half sine wave; Peak acceleration: 300m/S2; Pulse width: 6ms; Axial direction of impact: 6 directions; Number of impacts: 3 in each direction | ||||
| Voltage fluctuation and flicker | Pst≤1.0 dc≤3% | ||||
| P1t ≤ 0.65 dmax ≤ 4% d (t) value exceeds 3.3% ≤ 200ms | |||||
| Current harmonic emission | CLASS A IEC61000-3-2 {6} | ||||
| Acoustic noise | 55dB(A); Test distance 1m | ||||
| MTBF | MTBF≥100,000h | ||||
| Odor requirements | Do not produce peculiar smell and smell harmful to health. | ||||
| 1.7 Safety regulations and insulation level | |||||
| Parameter | Standard requirements | Comment | |||
| Input-output | 3000Vac/10mA//1min | No flashover, no breakdown | |||
| Input-Earth | 1500Vac/10mA//1min | No flashover, no breakdown | |||
| Output-Earth | 500Vdc/10mA//1min | No flashover, no breakdown | |||
| Insulation resistance | ≥10MΩ | Under normal atmospheric pressure, relative humidity < 90%, when the test voltage is 500Vdc, the power supply input to output, input to ground, output to ground insulation resistance ≥ 10 MΩ | |||
| 1.8 Mechanical properties | |||||
| Dimension (mm) | As shown in the figure below | ||||
| Weight (kg) | <0.5Kg | ||||
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].































































Reviews