Meanwell EDR-75 Series EDR-75-12| EDR-75-24| EDR-75-48 Switching Power Supply
The Meanwell EDR-75 Series delivers 75W with universal AC input, high efficiency, and compact DIN rail design, ideal for industrial use.
Model Number |
EDR-75-12 ,EDR-75-24 ,EDR-75-48 |
---|
Meanwell EDR-75 Series Switching Power Supply Description
The Meanwell EDR-75 Series Switching Power Supply is a reliable and compact solution for industrial applications. Designed for installation on DIN rail TS35/7.5 or TS35/15, this 75W power supply series features universal AC input, full-range protections, and high efficiency of up to 88.5%. With models including EDR-75-12, EDR-75-24, and EDR-75-48, this series supports a wide range of output voltages and currents to meet the demands of factory automation, semiconductor equipment, and other industrial control systems.
Product Features:
● Universal AC Input: Operates from 90-264VAC or 127-370VDC.
● Compact Design: Slim 32mm width optimizes space on DIN rails.
● High Efficiency: Up to 88.5% with natural air convection cooling.
● Full-Range Protections: Includes overload, overvoltage, over-temperature, and short-circuit protection.
● Durable Build: Metal housing enhances heat dissipation and ensures reliable performance in demanding environments.
● Global Compliance: Meets UL508, TUV EN62368-1, and BS EN/EN62368-1 safety standards.
● Wide Temperature Range: Operates from -20°C to +60°C with load derating at higher temperatures.
Applications:
● Factory automation systems.
● Semiconductor fabrication equipment.
● Electro-mechanical and industrial control systems.
Meanwell EDR-75 Series Switching Power Supply Specification:
MODEL | EDR-75-12 | EDR-75-24 | DR-75-48 | |
---|---|---|---|---|
OUTPUT | OUTPUT | 12V | 24V | 48V |
RATED CURRENT | 6.3A | 3.2A | 1.6A | |
CURRENT RANGE | 0 ~ 6.3A | 0 ~ 3.2A | 0 ~ 1.6A | |
RATED POWER | 75.6W | 76.8W | 76.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 12 ~ 14V | 24 ~ 28V | 48 ~ 55V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load | |||
HOLD UP TIME (Typ.) | 60ms/230VAC 12ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY (Typ.) | 85.50% | 87.50% | 88.50% | |
AC CURRENT (Typ.) | 1.45A/115VAC 0.9A/230VAC | |||
INRUSH CURRENT (Typ.) | 20A/115VAC 35A/230VAC | |||
LEAKAGE CURRENT | <1mA / 240VAC | |||
PROTECTION | OVERLOAD | 14 ~ 17V | 29 ~ 33V | 56 ~ 65V |
OVER VOLTAGE | Protection type : Shut down o/p voltage, re-power on to recover | |||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60 (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85 , 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50 ) | |||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Ul508, TUV EN62368-1 approved;(meet EN60204-1) | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH | |||
EMC EMISSION | Compliance to EN55032 (CISPR32) Class A, EN61000-3-2,-3, CNS15936 Class A | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55035, EN61000-6-2 ( EN50082-2), BS EN/ BS EN/ BS EN/ BS EN/ heavy industry level, EAC TP TC 020 | |||
OTHERS | MTBF | 2777.2K hrs min. Telcordia SR-332 (Bellcore) ; 506.6K hrs min. MIL-HDBK-217F (25 ) | ||
DIMENSION | 32*125.2*102mm (W*H*D) | |||
PACKING | 0.51Kg; 28pcs/15.3Kg/1.22CUFT | |||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. ℃ 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 & 47 parallel capacit μ μ F F or. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. Derating may be needed under low input voltage. Please check the derating curve for more details. 7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude highe ℃ ℃ r than 2000m(6500ft). ※ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell EDR-75 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].
Reviews
There are no reviews yet.