Meanwell LPV-100 Series Switching Power Supply
The Meanwell LPV-100 Series Switching Power Supply is a reliable and efficient solution for LED applications, available in multiple voltage options (5V, 12V, 15V, 24V, 36V, 48V) with IP67 protection and built-in safety features.
Model Number |
LPV-100-5 ,LPV-100-12 ,LPV-100-15 ,LPV-100-24 ,LPV-100-36 ,LPV-100-48 |
---|
Meanwell LPV-100 Series Switching Power Supply Description
The Meanwell LPV-100 Series Switching Power Supply is a highly reliable and cost-effective solution designed for powering LED-related fixtures and appliances. This series provides a universal AC input range and is fully encapsulated with an IP67 protection rating, making it suitable for both indoor and outdoor applications. It’s engineered to withstand a 300VAC surge for up to 5 seconds and comes with built-in protections against short circuits, overloads, and overvoltages.
Product Features:
● Universal AC Input: Supports full input range from 90-264V AC for worldwide use.
● IP67 Protection: Fully encapsulated design with an IP67 rating for outdoor and harsh environmental conditions.
● Surge Protection: Withstands 300VAC surge input for 5 seconds, ensuring reliable operation even in unstable power environments.
● Multiple Protections: Includes short circuit, overload, and overvoltage protection for safe and secure operation.
● Plastic Case: Fully isolated plastic case provides durability and safety.
● Cooling by Free Air Convection: No fans required; relies on natural convection for cooling.
● 100% Full Load Burn-in Test: Ensures maximum reliability and performance under full load conditions.
● Low Cost & High Reliability: Cost-effective without compromising on quality and durability.
● LED Fixture Compatibility: Ideal for powering LED decorations, advertisement devices, and related fixtures.
Meanwell LPV-100 Series Switching Power Supply Specification:
MODEL | LPV-100-5 | LPV-100-12 | LPV-100-15 | LPV-100-24 | LPV-100-36 | LPV-100-48 | ||||
---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V | |||
RATED CURRENT | 12A | 8.5A | 6.7A | 4.2A | 2.8A | 2.1A | ||||
CURRENT RANGE | 0 ~ 12A | 0 ~ 8.5A | 0 ~ 6.7A | 0 ~ 4.2A | 0 ~ 2.8A | 0 ~ 2.1A | ||||
RATED POWER | 60W | 102W | 100.5W | 100.8W | 100.8W | 100.8W | ||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | ||||
VOLTAGE TOLERANCE Note.3 | ±8.0% | ±5.0% | ||||||||
LINE REGULATION | ±1.0% | |||||||||
LOAD REGULATION | ±6.0% | ±2.0% | ||||||||
SETUP, RISE TIME | Note.6 | 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC | ||||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 14ms/115VAC at full load | |||||||||
INPUT | VOLTAGE RANGE | Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 80% | 85% | 87% | 88% | 88% | 89% | ||||
AC CURRENT | 2.2A/115VAC 1.2A/230VAC | |||||||||
INRUSH CURRENT(Typ.) | COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC | |||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC | |||||||||
LEAKAGE CURRENT | 0.25mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | ||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | ||||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70℃ (Refer to "Derating Curve") | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC | SAFETY STANDARDS | UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(Note12), EAC TP TC 004,IP67, IEC62368-1 , BS EN/EN62368-1 approved | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A(≤80% load), BS EN/EN61000-3-3, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light industry level, EAC TP TC 020 | |||||||||
OTHERS | MTBF | 4497.1K hrs min. Telcordia SR-332 (Bellcore) ; | 681.6Khrs min. | MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 190*52*37mm (L*W*H) | |||||||||
PACKING | 0.61Kg;20pcs/13.2Kg/0.57CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||||||
4. Derating may be needed under low input voltage. Please check the static characteristics for more details. | ||||||||||
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | ||||||||||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) | ||||||||||
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. | ||||||||||
7. Suitable for indoor use or outdoor use without direct sunlight exposure. | ||||||||||
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | ||||||||||
9. Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information. | ||||||||||
10. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf | ||||||||||
11. This product is not intended for LED lighting luminaire applications in the EU and China.(In the EU and China the LPF/NPF/XLG/XLC/XLN series | ||||||||||
are recommended.) | ||||||||||
12. R-41027766 (GZ factory) only for 12V,24V / R-62002178 (ID factory) for 5V~48V | ||||||||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:LPV-100-SPEC 2024-12-12 |
Download Resource:
Meanwell LPV-100 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].