Meanwell LRS-150 Series Switching Power Supply

The Meanwell LRS-150 Series Switching Power Supply offers efficient, reliable power solutions for LED and industrial applications. With multiple voltage options, it is perfect for various power needs.

Model Number

LRS-150-12

,

LRS-150-15

,

LRS-150-24

,

LRS-150-36

,

LRS-150-48

This product is currently out of stock and unavailable.

SKU: MWLRS150XX Categories: ,
MeanWell
Description

Meanwell LRS-150 Series Switching Power Supply Description

The Meanwell LRS-150 Series Switching Power Supply is a high-performance, reliable power solution designed for industrial applications, including LED displays and other power-sensitive equipment. This series offers multiple voltage options—12V, 15V, 24V, 36V, and 48V—making it versatile for various use cases. With its compact design, high efficiency, and long lifespan, it is the ideal choice for power-hungry, compact installations.

Product Features:
● High Efficiency: Up to 90% efficiency, reducing energy consumption and heat generation.
● Wide Input Voltage Range: 90-264VAC input, compatible with global power grids.
● Multiple Protection Functions: Includes over-load, over-voltage, and over-temperature protection to ensure safe and reliable operation.
● Compact Design: Small size suitable for installations where space is limited.
● Long Lifespan: Built with high-quality components for long-term reliability.
● Global Certifications: CE, UL, and other safety certifications ensure product quality and safety.

Meanwell LRS-150 Series Switching Power Supply Specification:

MODELLRS-150-12LRS-150-15LRS-150-24LRS-150-36LRS-150-48
OUTPUTDC VOLTAGE12V15V24V36V48V
RATED CURRENT12.5A10A6.5A4.3A3.3A
CURRENT RANGE0 ~ 12.5A0 ~ 10A0 ~ 6.5A0 ~ 4.3A0 ~ 3.3A
RATED POWER150W150W156W154.8W158.4W
RIPPLE & NOISE (max.) Note.2150mVp-p150mVp-p200mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE10.2 ~ 13.8V13.5 ~ 18V21.6 ~ 28.8V32.4 ~ 39.6V43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION Note.4±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION Note.5±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)40ms/230VAC 35ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)87.50%88.50%89%89%90%
AC CURRENT (Typ.)3A/115VAC 1.7A/230VAC
INRUSH CURRENT (Typ.)COLD STAR 60A/230VAC
LEAKAGE CURRENT<0.75mA / 240VAC
PROTECTIONOVER LOAD110 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE13.8 ~ 16.2V18.75 ~ 21.75V28.8 ~ 33.6V41.4 ~ 48.6V55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREShut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.-30 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT±0.03%/ (0 ~ 50)
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 7)UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,KC K60950-1(for LRS-150-12 only),
SAFETY STANDARDSBIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9), AS/NZS 62368.1(by CB) approved
WITHSTAND VOLTAGEI/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSIONCompliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤75% Load),
BS EN/EN61000-3-3,GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,
heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)
OTHERSMTBF2707.7K hrs min. Telcordia SR-332 (Bellcore) ; 558.2Khrs min. MIL-HDBK-217F (25)
DIMENSION159*97*30mm (L*W*H)
PACKING0.48Kg ; 30pcs/15.4Kg/0.75CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
8. The ambient temperature derating of 5/1000m is needed for operating altitude greater than 2000m (6500ft).
9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Download Resource:
Meanwell LRS-150 Series Switching Power Supply Specification

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].