Meanwell LRS-150(F) Series Switching Power Supply
$26.99 – $27.99
The Meanwell LRS-150F Series offers high efficiency and a compact design with a variety of output voltages. Ideal for industrial applications, featuring built-in protections and active power factor correction.
Model Number |
LRS-150-5 ,LRS-150F-5 ,LRS-150F-12 ,LRS-150F-15 ,LRS-150F-24 ,LRS-150F-36 ,LRS-150F-48 |
---|
Meanwell LRS-150(F) Series Switching Power Supply Description
The Meanwell LRS-150F Series is a versatile and reliable range of switching power supplies designed for a variety of industrial applications. Known for its compact size and high efficiency, this series delivers stable power while ensuring minimal energy loss. Available in multiple output voltage options, the LRS-150F Series is suitable for powering a wide range of electronic equipment, including LED displays and industrial machinery.
Product Features:
● Compact and Space-Saving Design: The LRS-150F Series features a compact design that allows for easy integration into space-constrained environments.
● High Efficiency: With an efficiency of up to 90%, this power supply minimizes energy waste and reduces operating costs.
● Active Power Factor Correction (PFC): Ensures a high power factor and low harmonic distortion, improving overall efficiency and reducing energy loss.
● Wide Input Voltage Range: Supports a universal input voltage range from 90-264VAC, making it suitable for use in various global regions.
● Multiple Output Voltages: Available in a variety of output voltages, including 5V, 12V, 15V, 24V, 36V, and 48V, to meet diverse power requirements.
● Built-in Protections: Includes short circuit, overload, and over-voltage protections, ensuring the safety and longevity of connected devices.
● Cooling System: Designed with a fanless cooling system for quiet operation and reliable performance.
Meanwell LRS-150F Series Switching Power Supply Specification:
MODEL | LRS-150F-5 | LRS-150F-12 | LRS-150F-15 | LRS-150F-24 | LRS-150F-36 | LRS-150F-48 | |
---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 22A | 12.5A | 10A | 6.5A | 4.3A | 3.3A | |
CURRENT RANGE | 0 ~ 22A | 0 ~ 12.5A | 0 ~ 10A | 0 ~ 6.5A | 0 ~ 4 .3A | 0 ~ 3.3A | |
RATED POWER | 110W | 150W | 150W | 156W | 154.8W | 158.4W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28 .8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±2 .0% | ±1 .0% | ±1 .0% | ±1 .0% | ±1 .0% | ±1 .0% | |
LINE REGULATION Note.4 | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | |
LOAD REGULATION Note.5 | ±1 .0% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | |
SETUP, RISE TIME | 500ms , 30ms/230VAC 500ms ,30ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 85% | 87.50% | 89% | 89% | 89% | 90% | |
AC CURRENT (Typ.) | 3A/115VAC 1.7A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD STAR 60A/230VAC | ||||||
LEAKAGE CURRENT | <0 .75mA / 240VAC | ||||||
PROTECTION | OVER LOAD | 110 ~ 140% rated output power | |||||
Protection type : Hiccup mode , recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18.75 ~ 21 .75V | 28.8 ~ 33.6V | 41.4 ~ 48 .6V | 55.2 ~ 64.8V | |
Protection type : Shut down o/p voltage , re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage , re-power on to recover | ||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0 .03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz , 5G 10min./1cycle , 60min. each along X , Y, Z axes | ||||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to BS EN/EN61558 , BS EN/EN50178 , BS EN/EN60664-1 , BS EN/EN62477-1; altitude up to | ||||||
2000 meters | |||||||
SAFETY & EMC (Note 7) | SAFETY STANDARDS | UL62368-1 , TUV BS EN/EN62368-1 , BS EN/EN60335-1 , BS EN/EN61558-1/-2-16 ,GB 4943 . 1 , BSMI CNS15598-1 , EACTPTC004 , AS/NZS 62368 . 1(by CB) , | |||||
BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved | |||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1 .25KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG , O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤80% Load ), GB17625 .1,GB/T 9254 .1, BSMI CNS15936, EACTPTC 020 | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TPTC 020 | ||||||
OTHERS | MTBF | 2761.8K hrs min. Telcordia SR-332 (Bellcore) ; 592.4Khrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 159*97*30mm (L*W*H) | ||||||
PACKING | 0.48Kg ; 30pcs/15 .4Kg/0 .75CUFT | ||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, ratedIoad and 25℃ of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 4. Line reguIation is measured from Iow Iine to high Iine at ratedIoad. 5. Load reguIation is measured from 0% to 100% ratedIoad. 6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time. 7. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 8. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m (6500ft). 9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. ※ product LiabiIity DiscIaimer :For detaiIed information, pIease refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell LRS-150F Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].