■ Features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- 1U low profile
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption<0.75W
- 100% full load burn-in test
- High operating temperature up to 70℃
- Operating altitude up to 5000 meters (Note.8)
- High efficiency, long life and high reliability
- 3 years warranty
Original price was: $35.00.$27.99Current price is: $27.99.
LRS-200 series is a 200W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch}, the entire series provides an output voltage of 5V for LED display.
ln addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation of LRS-200 that the whole series operates from -25℃ through 70℃ under air convection without a fan. Delivering an extremely low no load power consumption (less than 0.75W}, it allows the end system to easily meet the worldwide energy requirement. LRS-200 has the complete protection functions and 5G anti- vibration capability; it is complied with the international safety regulations such as UL 60950-1.
LRS-200 series serves as a high price-to-performance power supply solution for LED display applications.
ITEM | LRS-200-5 | |
OUTPUT | DC VOLTAGE | 5V |
RATED CURRENT | 40A | |
CURRENT RANGE | 0 ~ 40A | |
RATED POWER | 200W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | |
LINE REGULATION Note.4 | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | |
SETUP, RISE TIME | 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 87% | |
AC CURRENT (Typ.) | 4A/115VAC 2.2A/230VAC | |
INRUSH CURRENT (Typ.) | COLD STAR 60A/115VAC 60A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | 110 ~ 140% rated output power | |
OVER LOAD | Protection type : Hiccup mode, recovers automatically after fault condition is removed | |
5.75 ~ 6.75V | ||
OVER VOLTAGE | Protection type : Hiccup mode, recovers automatically after fault condition is removed | |
OVER TEMPERATURE | Hiccup mode, recovers automatically after fault condition is removed | |
ENVIRONMENT | WORKING TEMP. | -25 ~ 70℃ (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ 85℃, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY | SAFETY STANDARDS | UL60950-1, BSMI CNS14336-1, EAC TP TC 004 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |
EMC EMISSION | Compliance to BSMI CNS13438, EAC TP TC 020 | |
EMC IMMUNITY | Compliance to EAC TP TC 020 | |
MTBF | 347.5K hrs min. MIL-HDBK-217F (25℃) | |
OTHERS | DIMENSION | 215*115*30mm (L*W*H) |
PACKING | 0.66Kg; 15pcs/10.9Kg/0.78CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||
4. Line regulation is measured from low line to high line at rated load. | ||
5. Load regulation is measured from 0% to 100% rated load. | ||
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. | ||
7. The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-200 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC}. | ||
8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft}. |