Meanwell LRS-50 Series Switching Power Supply

The Meanwell LRS-50 Series Power Supply offers reliable, compact, and efficient power for LED lighting and industrial devices, with multiple voltage options.

Model Number

LRS-50-3.3

,

LRS-50-5

,

LRS-50-12

,

LRS-50-15

,

LRS-50-24

,

LRS-50-36

,

LRS-50-48

This product is currently out of stock and unavailable.

SKU: MWLRS50XX Categories: ,
MeanWell
Description

Meanwell LRS-50 Series Switching Power Supply Description

The Meanwell LRS-50 Series Switching Power Supply is a compact and highly efficient solution for powering LED lighting, small appliances, and other electronic devices. Known for its reliability and cost-effectiveness, the LRS-50 Series offers a wide range of output voltages, including 3.3V, 5V, 12V, 15V, 24V, 36V, and 48V, making it suitable for a variety of applications. Designed to provide continuous power in demanding environments, this power supply ensures optimal performance while maintaining energy efficiency.

Product Features:
● Compact Design: Ideal for applications where space is limited, providing high efficiency in a small form factor.
● Wide Input Voltage Range: Supports 90-264V AC, making it compatible with global power sources.
● Multiple Output Voltages: Available in various output voltages including 3.3V, 5V, 12V, 15V, 24V, 36V, and 48V to suit a wide range of devices.
● High Efficiency: Provides up to 88% efficiency, reducing power consumption and improving cost-effectiveness.
● Built-in Protection: Overload, overvoltage, and short circuit protection to ensure safe and secure operation.
● Reliable Performance: Designed for continuous use with a high mean time between failures (MTBF).
● Cooling by Free Air Convection: No fan required, ensuring quiet operation and improved lifespan.
● Low Cost and High Reliability: Offers excellent value for a power supply with superior performance and durability.

Meanwell LRS-50 Series Switching Power Supply Specification:

MODELLRS-50-3.3LRS-50-5LRS-50-12LRS-50-15LRS-50-24LRS-50-36LRS-50-48
OUTPUTDC VOLTAGE3.3V5V12V15V24V36V48V
RATED CURRENT10A10A4.2A3.4A2.2A1.45A1.1A
CURRENT RANGE0 ~ 10A0 ~ 10A0 ~ 4.2A0 ~ 3.4A0 ~ 2.2A0 ~ 1.45A0 ~ 1.1A
RATED POWER33W50W50.4W51W52.8W52.2W52.8W
RIPPLE & NOISE (max.) Note.280mVp-p80mVp-p120mVp-p120mVp-p150mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE2.97 ~ 3.6V4.5 ~ 5.5V10.2 ~ 13.8V13.5 ~ 18V21.6 ~ 28.8V32.4 ~ 39.6V43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3±3.0%±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION Note.4±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION Note.5±2.0%±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)30ms/230VAC 12ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC 120 ~ 373VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)80%83%86%88%88%89%90%
AC CURRENT (Typ.)0.95A/115VAC 0.56A/230VAC
INRUSH CURRENT (Typ.)COLD START 45A/230VAC
LEAKAGE CURRENT<0.75mA / 240VAC
PROTECTIONOVER LOAD110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE3.8 ~ 4.45V5.9~ 7.3V13.8 ~ 17.2V18.75 ~ 25.75V28.8 ~ 36.6V41.4 ~ 51.6V55.2 ~ 67.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.-30 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT±0.03%/ (0 ~ 50)
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters
SAFETY & EMC (Note 9)SAFETY STANDARDSUL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC K60950-1(for LRS-50-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10) approved
WITHSTAND VOLTAGEI/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSIONCompliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035,
heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)
OTHERSMTBF3149.8K hrs min. Telcordia SR-332 (Bellcore) ; 561.6Khrs min. MIL-HDBK-217F (25)
DIMENSION99*82*30mm (L*W*H)
PACKING0.21Kg; 60pcs/14Kg/0.93CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
7. 3.3V,5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications.
8. The ambient temperature derating of 5/1000m is needed for operating altitude greater than 2000m(6500ft).
9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
10. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Download Resource:
Meanwell LRS-50 Series Switching Power Supply Specification

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].