Meanwell LRS-50 Series Switching Power Supply
The Meanwell LRS-50 Series Power Supply offers reliable, compact, and efficient power for LED lighting and industrial devices, with multiple voltage options.
Model Number |
LRS-50-3.3 ,LRS-50-5 ,LRS-50-12 ,LRS-50-15 ,LRS-50-24 ,LRS-50-36 ,LRS-50-48 |
---|
Meanwell LRS-50 Series Switching Power Supply Description
The Meanwell LRS-50 Series Switching Power Supply is a compact and highly efficient solution for powering LED lighting, small appliances, and other electronic devices. Known for its reliability and cost-effectiveness, the LRS-50 Series offers a wide range of output voltages, including 3.3V, 5V, 12V, 15V, 24V, 36V, and 48V, making it suitable for a variety of applications. Designed to provide continuous power in demanding environments, this power supply ensures optimal performance while maintaining energy efficiency.
Product Features:
● Compact Design: Ideal for applications where space is limited, providing high efficiency in a small form factor.
● Wide Input Voltage Range: Supports 90-264V AC, making it compatible with global power sources.
● Multiple Output Voltages: Available in various output voltages including 3.3V, 5V, 12V, 15V, 24V, 36V, and 48V to suit a wide range of devices.
● High Efficiency: Provides up to 88% efficiency, reducing power consumption and improving cost-effectiveness.
● Built-in Protection: Overload, overvoltage, and short circuit protection to ensure safe and secure operation.
● Reliable Performance: Designed for continuous use with a high mean time between failures (MTBF).
● Cooling by Free Air Convection: No fan required, ensuring quiet operation and improved lifespan.
● Low Cost and High Reliability: Offers excellent value for a power supply with superior performance and durability.
Meanwell LRS-50 Series Switching Power Supply Specification:
MODEL | LRS-50-3.3 | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 | |
---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 10A | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 10A | 0 ~ 4.2A | 0 ~ 3.4A | 0 ~ 2.2A | 0 ~ 1.45A | 0 ~ 1.1A | |
RATED POWER | 33W | 50W | 50.4W | 51W | 52.8W | 52.2W | 52.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 80% | 83% | 86% | 88% | 88% | 89% | 90% | |
AC CURRENT (Typ.) | 0.95A/115VAC 0.56A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION | OVER LOAD | 110 ~ 150% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 5.9~ 7.3V | 13.8 ~ 17.2V | 18.75 ~ 25.75V | 28.8 ~ 36.6V | 41.4 ~ 51.6V | 55.2 ~ 67.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | |||||||
SAFETY & EMC (Note 9) | SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC K60950-1(for LRS-50-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10) approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only) | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, | |||||||
heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only) | ||||||||
OTHERS | MTBF | 3149.8K hrs min. Telcordia SR-332 (Bellcore) ; 561.6Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 99*82*30mm (L*W*H) | |||||||
PACKING | 0.21Kg; 60pcs/14Kg/0.93CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||||
4. Line regulation is measured from low line to high line at rated load. | ||||||||
5. Load regulation is measured from 0% to 100% rated load. | ||||||||
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. | ||||||||
7. 3.3V,5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. | ||||||||
8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). | ||||||||
9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. | ||||||||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) | ||||||||
10. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | ||||||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell LRS-50 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].