Meanwell LRS-600 Series Switching Power Supply
The Meanwell LRS-600-12 is a 600W single-output switching power supply with high efficiency (92%), wide input voltage range, and robust protection functions, designed for industrial applications.
Model Number |
LRS-600-5 ,LRS-600-12 ,LRS-600-15 ,LRS-600-24 ,LRS-600-27 ,LRS-600-36 ,LRS-600-48 |
---|
Meanwell LRS-600 Series Switching Power Supply Description
The Meanwell LRS-600-12 is a 600W single-output enclosed-type switching power supply with a low-profile design, only 41mm in height. This series supports an input of either 115VAC or 230VAC (selectable via a switch), with output voltage options of 5V, 12V, 15V, 24V, 27V, 36V, and 48V. It offers high efficiency of up to 92% and is equipped with a long-life fan, allowing it to operate at full load in temperatures ranging from -20°C to +65°C. The LRS-600 series includes complete protection functions and 5G anti-vibration capability. It complies with international safety regulations and is a high-performance power supply solution for various industrial applications.
Product Features:
● Power Output: 600W with multiple output voltage options (5V, 12V, 15V, 24V, 27V, 36V, 48V).
● Input Voltage: Selectable input of 115VAC or 230VAC.
● High Efficiency: Up to 92% efficiency, helping reduce energy costs.
● Temperature Range: Operates in a wide temperature range of -20°C to +65°C.
● Anti-Vibration: 5G anti-vibration capability for industrial environments.
● Built-In Fan: Features a long-life fan for stable operation under full load.
● Protection Features: Overvoltage, overcurrent, short-circuit, and over-temperature protection.
● Safety Standards Compliant: Meets international safety certifications for reliability.
● Versatile Application: Ideal for industrial applications such as automation, communication equipment, and testing instruments.
Meanwell LRS-600 Series Switching Power Supply Specification:
MODEL | LRS-600-5 | LRS-600-12 | LRS-600-15 | LRS-600-24 | LRS-600-27 | LRS-600-36 | LRS-600-48 | |
---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 36V | 48V |
RATED CURRENT | 100A | 50A | 40A | 25A | 22.2A | 16.6A | 12.5A | |
CURRENT RANGE | 0 ~ 100A | 0 ~ 50A | 0 ~ 40A | 0 ~ 25A | 0 ~ 22.2A | 0 ~ 16.6A | 0 ~ 12.5A | |
RATED POWER | 500W | 600W | 600W | 600W | 599.4W | 597.6W | 600W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 270mVp-p | 360mVp-p | 360mVp-p | |
VOLTAGE ADJ. RANGE Note.3 | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 25.65 ~ 29.7V | 34.2 ~ 39.6V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.4 | ±2.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.6 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.7 | 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 20ms/230VAC 16ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE Note.8 | 90 ~ 132VAC / 180 ~ 264VAC by switch 255 ~ 370VDC (swith on 230VAC) | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 86% | 90% | 90% | 91% | 91% | 92% | 92% | |
AC CURRENT (Typ.) | 12A/115VAC 7.5A/230VAC | |||||||
INRUSH CURRENT (Typ.) | 35A/115VAC 60A/230VAC | |||||||
LEAKAGE CURRENT | <2mA / 240VAC | |||||||
PROTECTION (Note.9) | OVER LOAD | 105 ~ 150% rated output power | ||||||
Constant current limiting, unit will shutdown after 3 sec. re-power on to recover | ||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18 ~ 21V | 27.6 ~ 32.4V | 31 ~ 36.5V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||
FUNCTION | FAN ON/OFF CONTROL (Typ.) | RTH3≧50℃ FAN ON, ≦40℃ FAN OFF | ||||||
WORKING TEMP. | -20 ~ +65℃ (Refer to "Derating Curve") | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
BS IEC/UL 62368-1, EAC TP TC 004, KC62368-1(except for 5V), BIS IS13252(Part1):2010/IEC60950-1: 2005(NOTE 13),BSMI CNS15598-1,GB 4943.1,BS EN/EN61558-1,BS EN/EN61558-2-16 approved, Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1 | ||||||||
SAFETY STANDARDS | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||||||
SAFETY | ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to EAC TP TC 020, BSMI CNS15936,KC KSC 9832, KSC 9835 | |||||||
EMC IMMUNITY | Compliance to EAC TP TC 020,KC KSC 9832, KSC 9835 | |||||||
MTBF | 1533.4K hrs min. Telcordia SR-332(Bellcore) ; 301.7K hrs min. MIL-HDBK-217F (25℃) | |||||||
OTHERS | DIMENSION | 225*124*41mm (L*W*H) | ||||||
PACKING | 0.95Kg/12pcs/12.4Kg/0.77CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||
3. Voltage adjustment can only be operated within the input range of 100~120VAC or 200-240VAC. If the voltage adjustment is performed outside this range, it may cause abnormal output. | ||||||||
4. Tolerance : includes set up tolerance, line regulation and load regulation. | ||||||||
5. Line regulation is measured from low line to high line at rated load. | ||||||||
6. Load regulation is measured from 0% to 100% rated load. | ||||||||
7. Length of set up time is measured at cold start. Turning the power supply on/off frequently may lead to increase of the set up time. | ||||||||
8. Derating may be needed under low input voltages. Please refer to"Static Characteristics" sections for details. | ||||||||
9. Once protections are triggered, 4min(Typ.) of cold down time is required before restart. | ||||||||
10. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). | ||||||||
11. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions: | ||||||||
a) the end-devices is used within the European Union, and | ||||||||
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and | ||||||||
c) the power supply is: | ||||||||
- installed in end-devices with average or continuous input power greater than 75W, or | ||||||||
- belong to part of a lighting system Exception: | ||||||||
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2 | ||||||||
a) professional equipment with a total rated input power greater than 1000W; | ||||||||
b) symmetrically controlled heating elements with a rated power less than or equal to 200W | ||||||||
12. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. | ||||||||
13. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | ||||||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell LRS-600 Series Switching Power Supply Specification.pdf
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].