Meanwell LRS-600 Series Switching Power Supply Description

The Meanwell LRS-600-12 is a 600W single-output enclosed-type switching power supply with a low-profile design, only 41mm in height. This series supports an input of either 115VAC or 230VAC (selectable via a switch), with output voltage options of 5V, 12V, 15V, 24V, 27V, 36V, and 48V. It offers high efficiency of up to 92% and is equipped with a long-life fan, allowing it to operate at full load in temperatures ranging from -20°C to +65°C. The LRS-600 series includes complete protection functions and 5G anti-vibration capability. It complies with international safety regulations and is a high-performance power supply solution for various industrial applications.

Product Features:
● Power Output: 600W with multiple output voltage options (5V, 12V, 15V, 24V, 27V, 36V, 48V).
● Input Voltage: Selectable input of 115VAC or 230VAC.
● High Efficiency: Up to 92% efficiency, helping reduce energy costs.
● Temperature Range: Operates in a wide temperature range of -20°C to +65°C.
● Anti-Vibration: 5G anti-vibration capability for industrial environments.
● Built-In Fan: Features a long-life fan for stable operation under full load.
● Protection Features: Overvoltage, overcurrent, short-circuit, and over-temperature protection.
● Safety Standards Compliant: Meets international safety certifications for reliability.
● Versatile Application: Ideal for industrial applications such as automation, communication equipment, and testing instruments.

Meanwell LRS-600 Series Switching Power Supply Specification:

MODELLRS-600-5LRS-600-12LRS-600-15LRS-600-24LRS-600-27LRS-600-36LRS-600-48
OUTPUTDC VOLTAGE5V12V15V24V27V36V48V
RATED CURRENT100A50A40A25A22.2A16.6A12.5A
CURRENT RANGE0 ~ 100A0 ~ 50A0 ~ 40A0 ~ 25A0 ~ 22.2A0 ~ 16.6A0 ~ 12.5A
RATED POWER500W600W600W600W599.4W597.6W600W
RIPPLE & NOISE (max.) Note.2200mVp-p200mVp-p200mVp-p240mVp-p270mVp-p360mVp-p360mVp-p
VOLTAGE ADJ. RANGE Note.34.75 ~ 5.5V11.4 ~ 13.2V14.25 ~ 16.5V22.8 ~ 26.4V25.65 ~ 29.7V34.2 ~ 39.6V45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.4±2.0%±1.5%±1.0%±1.0%±1.0%±1.0%±1.0%
LINE REGULATION Note.5±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
LOAD REGULATION Note.6±2.0%±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%
SETUP, RISE TIME Note.71300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)20ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE Note.890 ~ 132VAC / 180 ~ 264VAC by switch 255 ~ 370VDC (swith on 230VAC)
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)86%90%90%91%91%92%92%
AC CURRENT (Typ.)12A/115VAC 7.5A/230VAC
INRUSH CURRENT (Typ.)35A/115VAC 60A/230VAC
LEAKAGE CURRENT<2mA / 240VAC
PROTECTION (Note.9)OVER LOAD105 ~ 150% rated output power
Constant current limiting, unit will shutdown after 3 sec. re-power on to recover
OVER VOLTAGE5.75 ~ 6.75V13.8 ~ 16.2V18 ~ 21V27.6 ~ 32.4V31 ~ 36.5V41.4 ~ 48.6V55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREShut down o/p voltage, re-power on to recover
FUNCTIONFAN ON/OFF CONTROL (Typ.)RTH350 FAN ON, 40 FAN OFF
WORKING TEMP.-20 ~ +65 (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 90% RH non-condensing
ENVIRONMENTSTORAGE TEMP., HUMIDITY-40 ~ +85, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ (0 ~ 50)
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters
BS IEC/UL 62368-1, EAC TP TC 004, KC62368-1(except for 5V), BIS IS13252(Part1):2010/IEC60950-1: 2005(NOTE 13),BSMI CNS15598-1,GB 4943.1,BS EN/EN61558-1,BS EN/EN61558-2-16 approved, Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1
SAFETY STANDARDS
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
SAFETYISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
EMC EMISSIONCompliance to EAC TP TC 020, BSMI CNS15936,KC KSC 9832, KSC 9835
EMC IMMUNITYCompliance to EAC TP TC 020,KC KSC 9832, KSC 9835
MTBF1533.4K hrs min. Telcordia SR-332(Bellcore) ; 301.7K hrs min. MIL-HDBK-217F (25)
OTHERSDIMENSION225*124*41mm (L*W*H)
PACKING0.95Kg/12pcs/12.4Kg/0.77CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Voltage adjustment can only be operated within the input range of 100~120VAC or 200-240VAC. If the voltage adjustment is performed outside this range, it may cause abnormal output.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 0% to 100% rated load.
7. Length of set up time is measured at cold start. Turning the power supply on/off frequently may lead to increase of the set up time.
8. Derating may be needed under low input voltages. Please refer to"Static Characteristics" sections for details.
9. Once protections are triggered, 4min(Typ.) of cold down time is required before restart.
10. The ambient temperature derating of 5/1000m is needed for operating altitude greater than 2000m(6500ft).
11. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c) the power supply is:
- installed in end-devices with average or continuous input power greater than 75W, or
- belong to part of a lighting system Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200W
12. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
13. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Download Resource:
Meanwell LRS-600 Series Switching Power Supply Specification.pdf

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].