Meanwell NDR-240 Series Switching Power Supply
The Meanwell NDR-240 Series Switching Power Supply provides efficient, stable power for industrial applications with 240W output in 24V and 48V options.
Model Number |
NDR-240-24 ,NDR-240-48 |
---|
Meanwell NDR-240 Series Switching Power Supply Description
The Meanwell NDR-240 Series Switching Power Supply is a highly efficient and reliable power solution designed for industrial applications. It features a compact, single-output design and is ideal for DIN rail mounting, making it perfect for automation systems, control machinery, and other industrial devices. With multiple voltage options, including 24V and 48V, the NDR-240 series ensures a versatile and stable power supply solution. It also incorporates robust protection features, including over-voltage, over-current, and over-temperature safeguards, ensuring reliable performance in demanding environments.
Product Features:
● High Efficiency: Offers up to 90% efficiency, ensuring minimal energy waste and heat production.
● Wide Input Voltage Range: 90-264VAC input, compatible with global power standards.
● DIN Rail Mounting: Compact design for easy installation in industrial settings with DIN rail TS35/7.5 or TS35/15.
● Protection Features: Includes over-voltage, over-current, short-circuit, and over-temperature protection.
● Rugged Build: Designed to withstand harsh industrial conditions with high vibration resistance and a wide operating temperature range.
● Global Certifications: UL508, TUV, CE, and other safety certifications ensure compliance with industry standards.
Meanwell NDR-240 Series Switching Power Supply Specification:
MODEL | NDR-240-24 | NDR-240-48 | |
---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 48V |
RATED CURRENT | 10A | 5A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | |
RATED POWER | 240W | 240W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 24 ~ 28V | 48 ~ 55V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load | ||
HOLD UP TIME (Typ.) | 28ms/230VAC 22ms/115VAC at full load | ||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | ||
EFFICIENCY (Typ.) | 88.50% | 90% | |
AC CURRENT (Typ.) | 2.5A/115VAC 1.3A/230VAC | ||
INRUSH CURRENT (Typ.) | 20A/115VAC 35A/230VAC | ||
LEAKAGE CURRENT | <1mA / 240VAC | ||
PROTECTION | OVERLOAD | 105 ~ 130% rated output power | |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 29 ~ 33V | 56 ~ 65V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to "Derating Curve") | |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI CNS14336-1, BIS IS13252(Part1): 2010/IEC 60950-1:2005(NOTE 8) , | |
KC K60950-1(for 48V only)approved; (meet BS EN/EN60204-1) | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH | ||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438, | ||
KSC 9832(for 48V only) | |||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), | ||
BS EN/EN61204-3, heavy industry level, EAC TP TC 020,KSC 9835(for 48V only) | |||
OTHERS | MTBF | 1645.2K hrs min. Telcordia SR-332 (Bellcore) ; 230.2K hrs min. MIL-HDBK-217F (25℃) | |
DIMENSION | 63*125.2*113.5mm (W*H*D) | ||
PACKING | 1Kg; 12pcs/13Kg/1.22CUFT | ||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. | |||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||
4. Derating may be needed under low input voltage. Please check the derating curve for more details. | |||
5. lnstallation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended. | |||
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” | |||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) | |||
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | |||
8. Some model may not have the BlS logo, please contact your MEAN WELL sales for more information. | |||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell NDR-240 Series Switching Power Supply Specification.pdf
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].