Meanwell NDR-480 Series Switching Power Supply

The Meanwell NDR-480 Series Switching Power Supply provides 480W of efficient, stable power for industrial applications. Available in 24V and 48V output options.

Model Numbe

NDR-480-24

,

NDR-480-48

This product is currently out of stock and unavailable.

SKU: MWNDR480XX Categories: ,
MeanWell
Description

Meanwell NDR-480 Series Switching Power Supply Description

The Meanwell NDR-480 Series Switching Power Supply is a high-performance, reliable power solution designed for industrial applications. Offering a 480W output, this power supply is ideal for use in control systems, automation machinery, and other industrial equipment. Available in 24V and 48V models, it features a robust DIN rail mount design, making installation easy and efficient. The NDR-480 Series ensures stable power with high efficiency, built-in protections against over-voltage, over-current, and over-temperature, and a wide input voltage range to suit diverse power grids.

Product Features:
● High Efficiency: Up to 92.5% efficiency for reduced energy loss.
● Wide Input Voltage Range: 90-264VAC input, making it suitable for international use.
● DIN Rail Mount: Easy installation on TS35/7.5 or TS35/15 DIN rails for industrial setups.
● Protection Features: Includes over-voltage, over-current, and over-temperature protection to safeguard devices.
● Compact and Durable: Designed for tough industrial environments with high resistance to vibration and extreme temperatures.
● Global Certifications: UL508, TUV, CE, and more to meet safety and quality standards.

Meanwell NDR-480 Series Switching Power Supply Specification:

MODELNDR-480-24NDR-480-48
OUTPUTDC VOLTAGE24V48V
RATED CURRENT20A10A
CURRENT RANGE0 ~ 20A0 ~ 10A
RATED POWER480W480W
RIPPLE & NOISE (max.) Note.2150mVp-p150mVp-p
VOLTAGE ADJ. RANGE24 ~ 28V48 ~ 55V
VOLTAGE TOLERANCE Note.3±1.0%±1.0%
LINE REGULATION±0.5%±0.5%
LOAD REGULATION±1.0%±1.0%
SETUP, RISE TIME1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)16ms/230VAC 16ms/115VAC at full load
INPUTVOLTAGE RANGE Note.490 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.98/115VAC, PF>0.94/230VAC at full load
EFFICIENCY (Typ.)92.50%92.50%
AC CURRENT (Typ.)4.8A/115VAC 2.4A/230VAC
INRUSH CURRENT (Typ.)20A/115VAC 35A/230VAC
LEAKAGE CURRENT<2mA / 240VAC
PROTECTION105 ~ 130% rated output power
OVERLOADProtection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
29 ~ 33V56 ~ 65V
OVER VOLTAGEProtection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATUREShut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENTWORKING TEMP.-20 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ (0 ~ 50)
VIBRATIONComponent:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)SAFETY STANDARDSUl508, TUV BS EN/EN62368-1, EAC TP TC 004 , BSMI CNS14336-1 , IS13252(Part1)/IEC60950-1(except for 48V) approved; (meet BS EN/EN60204-1)
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSIONCompliance to BS EN/EN55032 (CISPR32),BS EN/EN61204-3 Class B,BS EN/EN61000-3-2,-3,EAC TP TC 020,CNS13438 Class B
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN61204-3,
heavy industry level, EAC TP TC 020
OTHERSMTBF1041.6K hrs min. Telcordia SR-332 (Bellcore) ; 146.8K hrs min. MIL-HDBK-217F (25)
DIMENSION85.5*125.2*128.5mm (W*H*D)
PACKING1.5Kg; 8pcs/13Kg/0.9CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. lnstallation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended.
5. Derating may be needed under low input voltage. Please check the derating curve for more details.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Download Resource:
Meanwell NDR-480 Series Switching Power Supply Specification.pdf

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].