Meanwell RD-50 Series Switching Power Supply

The Meanwell RD-50 Series Switching Power Supply offers 50W output in 5V and 12V models. Compact, efficient, and reliable power for industrial applications.

Model Number

RD-50A

,

RD-50B

This product is currently out of stock and unavailable.

SKU: MWRD50X Categories: ,
MeanWell
Description

Meanwell RD-50 Series Switching Power Supply Description

The Meanwell RD-50 Series Switching Power Supply is a compact and efficient power solution designed for industrial applications. This series features dual output options, offering both 5V and 12V outputs for versatile power supply needs. The RD-50 series is perfect for use in automation equipment, control systems, and other industrial devices. With a wide input voltage range, high efficiency, and built-in protection features, it ensures stable and reliable power in demanding environments.

Product Features:
● Dual Output: Provides 5V and 12V outputs, allowing power to multiple devices.
● High Efficiency: Delivers up to 79% efficiency to reduce energy consumption.
● Wide Input Voltage Range: Compatible with input voltages from 88-264VAC, suitable for global use.
● Compact Design: Smaller form factor makes it ideal for installations with limited space.
● Protection Features: Includes overvoltage, overload, and short-circuit protection for safety and reliability.
● Built-in Cooling: Passive cooling for quiet operation.
● Global Certifications: UL62368-1, TUV, and BS EN/EN62368-1 certifications ensure compliance with international standards.

Meanwell RD-50 Series Switching Power Supply Specification:

MODELRD-50ARD-50B
OUTPUTOUTPUT NUMBERCH1CH2CH1CH2
DC VOLTAGE5V12V5V24V
RATED CURRENT6A2A4A1.4A
CURRENT RANGE Note.30 ~ 6A0 ~ 3A0 ~ 6A0 ~ 2A
RATED POWER54W53.6W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p80mVp-p150mVp-p
VOLTAGE ADJ. RANGECH1: 4.75 ~ 5.5VCH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3±2.0%±7.0%±2.0%±8%
LINE REGULATION Note.4±0.5%±1.5%±0.5%±1.5%
LOAD REGULATION Note.5±0.5%±3.0%±0.5%±3.0%
SETUP, RISE TIME500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)60ms/230VAC 10ms/115VAC at full load
INPUTVOLTAGE RANGE88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY(Typ.)78%79%
AC CURRENT (Typ.)1.3A/115VAC 0.8A/230VAC
INRUSH CURRENT (Typ.)COLD START 48A/230VAC
LEAKAGE CURRENT<2mA / 240VAC
PROTECTIONOVERLOAD110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGECH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP.-25 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ (0 ~ 50)on +5V output
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 6)SAFETY STANDARDSUL62368-1, TUV BS EN/EN62368-1, BIS IS 13252(Part 1):2010/IEC 60950-1:2005, EAC TP TC 004 approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSIONCompliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERSMTBF2981.9K hrs min. Telcordia SR-332 (Bellcore) ; 594.2K hrs min. MIL-HDBK-217F (25)
DIMENSION99*97*36mm (L*W*H)
PACKING0.41Kg; 45pcs/19.5Kg/0.94CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Download Resource:
Meanwell RD-50 Series Switching Power Supply Specification.pdf

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Meanwell RD-50 Series Switching Power Supply”

Your email address will not be published. Required fields are marked *

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].