The Meanwell RD-65 Series Switching Power Supply provides 65W of efficient power with 5V and 12V output options. Compact and reliable for industrial applications.
Model Number |
RD-65A ,RD-65B |
---|
Meanwell RD-65 Series Switching Power Supply Description
The Meanwell RD-65 Series Switching Power Supply is a compact, efficient, and reliable power solution designed for industrial applications. It provides 65W output with dual voltage options of 5V, 12V, and 24V, making it ideal for powering multiple devices in automation systems, LED displays, and control equipment. The RD-65 series is built for high reliability with built-in protection features, including over-voltage, over-current, and short-circuit protection. Its compact design and wide input voltage range make it suitable for various global installations.
Product Features:
● Dual Output: Provides 5V and 12V output, capable of powering multiple devices.
● High Efficiency: Delivers up to 79% efficiency, reducing energy consumption.
● Wide Input Voltage Range: Compatible with input voltages from 88-264VAC, ideal for international use.
● Protection Features: Includes over-voltage, over-current, and short-circuit protection for enhanced reliability.
● Compact Design: Small size perfect for installations in space-constrained environments.
● Global Certifications: UL62368-1, TUV, and BS EN/EN62368-1 certifications ensure safety and quality standards compliance.
Meanwell RD-65 Series Switching Power Supply Specification:
MODEL | RD-65A | RD-65B | |||
---|---|---|---|---|---|
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH1 | CH2 |
DC VOLTAGE | 5V | 12V | 5V | 24V | |
RATED CURRENT | 6A | 3A | 4A | 2A | |
CURRENT RANGE Note.6 | 0 ~ 8A | 0 ~ 4A | 0 ~ 8A | 0 ~ 3A | |
RATED POWER Note.6 | 66W | 68W | |||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±2.0% | +4,-8% | |
LINE REGULATION Note.4 | ±0.5% | ±1.5% | ±0.5% | ±2.0% | |
LOAD REGULATION Note.5 | ±0.5% | ±3.0% | ±0.5% | ±6.0% | |
SETUP, RISE TIME | 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 60ms/230VAC 14ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY(Typ.) | 78% | 77% | |||
AC CURRENT (Typ.) | 2A/115VAC 1.2A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 50A/230VAC | ||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | CH1: 5.75 ~ 6.75V | ||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70℃ (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃)on +5V output | ||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY & EMC (Note 7) | SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020 | ||||
OTHERS | MTBF | 2940.2K hrs min. Telcordia SR-332 (Bellcore) ; 541.0K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 129*98*38mm (L*W*H) | ||||
PACKING | 0.44Kg; 30pcs/14.2Kg/0.72CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. | |||||
3. Tolerance : includes set up tolerance, line regulation and load regulation, when multi-channel output, it is recommended that CH1 load > 10%. | |||||
4. Line regulation is measured from low line to high line at rated load. | |||||
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. | |||||
6. Each output can work within current range. But total output power can't exceed rated output power. | |||||
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” | |||||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) | |||||
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | |||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell RD-65 Series Switching Power Supply Specification.pdf
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].
Reviews
There are no reviews yet.