Meanwell RSD-60 Series Switching Power Supply
The Meanwell RSD-60 Series Switching Power Supply provides 60W output with 3.3V, 5V, 12V, and 24V options. Compact and reliable power for industrial use.
Model Number |
RSD-60G-3.3 ,RSD-60G-5 ,RSD-60G-12 ,RSD-60G-24 ,RSD-60L-3.3 ,RSD-60L-5 ,RSD-60L-12 ,RSD-60L-24 |
---|
Meanwell RSD-60 Series Switching Power Supply Description
The Meanwell RSD-60 Series Switching Power Supply is a reliable and efficient solution for industrial and commercial applications. Offering 60W of power output with various voltage options, including 3.3V, 5V, 12V, and 24V, it is ideal for automation systems, LED displays, and other devices requiring a stable power supply. This series features built-in protections such as overvoltage, overload, and short-circuit protection. The RSD-60 Series complies with international safety standards and is designed for use in harsh environments, offering high efficiency and thermal performance.
Product Features:
● Multiple Output Options: Available in 3.3V, 5V, 12V, and 24V, offering flexibility for different applications.
● High Efficiency: Typical efficiency of up to 91% ensures minimal energy loss and lower heat generation.
● Wide Input Voltage Range: Accepts input voltage from 9-36VDC, providing versatility for various environments.
● Built-in Protection: Includes overvoltage, overload, and short-circuit protections for enhanced safety.
● Compact and Reliable: Small size and rugged construction for use in tight spaces and harsh environments.
● Global Certifications: Complies with UL, TUV, and EN62368-1 standards for safety and reliability.
Meanwell RSD-60 Series Switching Power Supply Specification:
MODEL | RSD-60G-3.3 | RSD-60G-5 | RSD-60G-12 | RSD-60G-24 | RSD-60L-3.3 | RSD-60L-5 | RSD-60L-12 | RSD-60L-24 | |||
---|---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 24V | 3.3V | 5V | 12V | 24V | ||
RATED CURRENT | 12A | 12A | 5A | 2.5A | 12A | 12A | 5A | 2.5A | |||
CURRENT RANGE | 0 ~ 12A | 0 ~ 12A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 12A | 0 ~ 12A | 0 ~ 5A | 0 ~ 2.5A | |||
RATED POWER | 39.6W | 60W | 60W | 60W | 39.6W | 60W | 60W | 60W | |||
RIPPLE & NOISE (max.) Note.2 | 60mVp-p | 100mVp-p | 50mVp-p | 50mVp-p | 60mVp-p | 60mVp-p | 50mVp-p | 50mVp-p | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ±0.5% | ±0.3% | ±0.2% | |||
LOAD REGULATION | ±0.5% | ±0.5% | ±0.3% | ±0.2% | ±0.5% | ±0.5% | ±0.3% | ±0.2% | |||
SETUP, RISE TIME | 100ms, 60ms at full load | ||||||||||
HOLD UP TIME (Typ.) | Please refer to page 5 Hold up Time( Load de-rating curve ) | ||||||||||
INPUT | VOLTAGE RANGE CONTINUOUS | 9 ~ 36VDC | 18 ~ 72VDC | ||||||||
EFFICIENCY (Typ.) | 86.50% | 88% | 92% | 90% | 88.50% | 89% | 93% | 91.50% | |||
DC CURRENT (Typ.) | 2.1A/24VDC | 3A/24VDC | 0.95A/48VDC | 1.5A/48VDC | |||||||
INRUSH CURRENT (Typ.) | 20A/24VDC | 20A/48VDC | |||||||||
INTERRUPTION OF VOLTAGE SUPPLY | EN50155:2007-G type comply with S1 level(3ms) @full load,S2 level(10ms) @50% load; L type comply with S2 level(10ms) @full load | ||||||||||
EN50155:2017-Comply with S1 level | |||||||||||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power | |||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||||||||
OVER VOLTAGE | 4.3 ~ 5.3V | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | 4.3 ~ 4.95V | 5.75 ~ 7V | 13.8 ~ 16.2V | 27.6 ~ 32.4V | |||
Protection type : Shut down o/p voltage, re-power on to recover | |||||||||||
ENVIRONMENT | WORKING TEMP. | -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate) | |||||||||
WORKING HUMIDITY | 5 ~ 95% RH non-condensing | ||||||||||
STORAGE TEMP. | -40 ~ +85℃ | ||||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373 | ||||||||||
OPERATING ALTITUDE | 5000 meters | ||||||||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1 | |||||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC | ||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | ||||||||
Conducted | BS EN/EN55032 | Class A | |||||||||
Radiated | BS EN/EN55032 | Class B | |||||||||
Harmonic Current | BS EN/EN61000-3-2 | ----- | |||||||||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | |||||||||
EMC IMMUNITY | BS EN/EN55035 | ||||||||||
Parameter | Standard | Test Level / Note | |||||||||
ESD | BS EN/EN61000-4-2 | Level 3, ±8KV air ; Level 3, ±6KV contact | |||||||||
Radiated Field | BS EN/EN61000-4-3 | Level X, 20V/m | |||||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3, 2KV at power | |||||||||
Surge | BS EN/EN61000-4-5 | Level 3,1KV Line-Line, Level 3, 2KV Line-Earth | |||||||||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||||||||
RAILWAY STANDARD | Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC | ||||||||||
OTHERS | MTBF | 2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min. MIL-HDBK-217F (25℃) | |||||||||
DIMENSION | 128*60*25mm (L*W*H) | ||||||||||
PACKING | 0.29Kg; 48pcs/14.9Kg/0.75CUFT | ||||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25℃ of ambient temperature. | ||||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. | |||||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||||||||
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” | |||||||||||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) | |||||||||||
5. Strongly recommended that external output capacitance should not exceed 5000uF. | |||||||||||
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | |||||||||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell RSD-60 Series Switching Power Supply Specification.pdf
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].