Meanwell UHP-200A Series Switching Power Supply

$44.99$46.99

The Meanwell UHP-200A Series Power Supply offers 200W output with 4.2V, 4.5V, and 5V options. Fanless, efficient, and reliable for industrial applications.

Model Number

UHP-200A-5

,

UHP-200A-4.2

,

UHP-200A-4.5

MeanWell
Description

Meanwell UHP-200A Series Switching Power Supply Description

The Meanwell UHP-200A Series Switching Power Supply is a high-efficiency 200W power supply designed for a variety of industrial applications, offering output voltages of 4.2V, 4.5V, and 5V. With a low profile design and fanless operation, this power supply is ideal for installations where space is limited and noise is a concern. It is equipped with built-in protection functions such as short-circuit, overload, and over-voltage protection, ensuring safe and reliable operation. This series also features Power Factor Correction (PFC) for improved energy efficiency.

Product Features:
● Multiple Output Options: Available in 4.2V, 4.5V, and 5V configurations.
● Fanless Design: Quiet operation with enhanced thermal performance.
● Power Factor Correction (PFC): Ensures better energy efficiency.
● Built-in Protection: Short-circuit, overload, and over-voltage protection.
● Compact Design: Slim profile that saves space in crowded enclosures.
● Global Certifications: UL62368-1, TUV, EN62368-1, and more.
● Wide Input Range: Supports 90-264VAC for use worldwide.
● Operating Temperature: -30°C to +70°C for use in harsh environments.

Meanwell UHP-200A Series Switching Power Supply Specification:

MODELUHP-200A-4.2UHP-200A-4.5UHP-200A-5
OUTPUTDC VOLTAGE4.2V4.5V5V
RATED CURRENT40A40A40A
CURRENT RANGE0~40A0~40A0~40A
RATED POWER168W180W200W
RIPPLE & NOISE(max.) Note.2200mVp-p200mVp-p200mVp-p
VOLTAGE ADJ. RANGE4.0~4.4V4.3~4.7V4.7~5.3V
VOLTAGE TOLERANCE Note.3±4.0%±4.0%±4.0%
LINE REGULATION±0.5%±0.5%±0.5%
LOAD REGULATION±2.5%±2.5%±2.5%
SETUP, RISE TIME2000ms, 200ms/230VAC at full load, 3000ms, 200ms/115VAC at 80% load
HOLD UP TIME (Typ.)10ms/230VAC 10ms/115VAC
DC OK FUNCTIONPSU Turns on:DC ok; PSU turns off:DC fail
INPUTVOLTAGE RANGE Note.490 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF≥0.97/115VAC PF≥0.95/230VAC at full load
EFFICIENCY (Typ.)88%88%88.50%
AC CURRENT (Typ.)2.4A/115VAC 1.2A/230VAC
INRUSH CURRENT (Typ.)Cold start 85A/230VAC
LEAKAGE CURRENT<1.0mA / 240VAC
PROTECTIONOVERLOAD110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUITProtection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE4.6 ~ 6V5 ~ 6.4V5.6 ~ 7.1V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATUREProtection type : Shut down O/P voltage, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP.-30 ~ +70℃(Refer to “OUTPUT LOAD vs TEMPERATURE")
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/℃ (0 ~ 50℃)
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)SAFETY STANDARDSUL 62368-1,TUV BS EN/EN62368-1,GB 4943.1, EAC TP TC 004 approved
WITHSTAND VOLTAGEI/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
EMC EMISSION Note.8Compliance to BS EN/EN55032 (CISPR32),GB17625.1,GB/T 9254.1, BS EN/EN61000-3-2,-3,EAC TP TC 020
EMC IMMUNITYCompliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN55035, light industry level (surge 4KV),EAC TP TC 020
OTHERSMTBF1949.0 K hrs min. Telcordia SR-332 (Bellcore) ; 211.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION167*55*26mm (L*W*H)
PACKING0.42kg; 20pcs/ 11.4kg/0.76CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Transient response meansure shall be made with 10% load at least.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
8. Warnning: This equipment is compliant with Class A of ClSPR 32. ln a residential environment may cause radio interference.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Download Resource:
Meanwell UHP-200A Series Switching Power Supply Specification.

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].