Meanwell UHP-350 Series Switching Power Supply
The Meanwell UHP-350 Series Power Supply offers 350W output with 3.3V to 55V options. Fanless, efficient, and includes protection features for industrial use.
Model Number |
UHP-350-3.3 ,UHP-350-4.2 ,UHP-350-5 ,UHP-350-12 ,UHP-350-15 ,UHP-350-24 ,UHP-350-36 ,UHP-350-48 ,UHP-350-55 |
---|---|
Brand |
MEANWELL |
Meanwell UHP-350 Series Switching Power Supply Description
The Meanwell UHP-350 Series Switching Power Supply is designed for industrial applications, offering up to 350W output. It is available in multiple voltage options, including 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V, 48V, and 55V. This series features a slim, fanless design and high efficiency (up to 94%), making it ideal for installations with space constraints and where noise reduction is important. Built-in protection features such as short-circuit, overload, over-voltage, and over-temperature protection ensure the safety and longevity of your equipment. The UHP-350 operates in a wide temperature range and is compliant with global safety standards.
Product Features:
● High Efficiency: Up to 94% for better energy use.
● Multiple Output Options: 3.3V to 55V to suit different applications.
● Fanless Design: Silent operation, ideal for noise-sensitive environments.
● Built-in Protection: Overload, short-circuit, over-voltage, and over-temperature protection.
● Power Factor Correction (PFC): Enhanced energy efficiency.
● Compact, Slim Profile: Perfect for installations with limited space.
● Wide Operating Temperature: -30°C to +70°C.
● Reliable: MTBF of 285K hours at 25°C.
● Certifications: UL62368-1, TUV EN62368-1, and CE marked for safety.
Meanwell UHP-350 Series Switching Power Supply Specification:
MODEL | UHP-350-3.3 | UHP-350-4.2 | UHP-350-5 | UHP-350-12 | UHP-350-15 | UHP-350-24 | UHP-350-36 | UHP-350-48 | UHP-350-55 | |
---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V | 55V |
RATED CURRENT | 60A | 60A | 60A | 29.2A | 23.4A | 14.6A | 9.75A | 7.3A | 6.3A | |
RATED POWER | 198W | 252W | 300W | 350.4W | 351W | 350.4W | 351W | 350.4W | 350W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 3.2~3.5V | 3.6~4.4V | 4.5~5.5V | 11.4~12.6V | 14.3~15.8V | 22.8~25.2V | 34.2~37.8V | 45.6~50.4V | 45~58V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 2000ms, 80ms/230VAC; 3000ms, 80ms/115VAC at full load;550ms/230VAC for 55V setup time | |||||||||
HOLD UP TIME (Typ.) | 10ms/230VAC 10ms/115VAC | |||||||||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR (Typ.) | PF≥0.94/230VAC PF≥0.98/115VAC at full load | |||||||||
EFFICIENCY (Typ.) | 88.50% | 89% | 90% | 91% | 92% | 94% | 94% | 94% | 94% | |
AC CURRENT (Typ.) | 4A/115VAC 2A/230VAC | |||||||||
INRUSH CURRENT (Typ.)Note8 | Cold start 30A/115VAC 60A/230VAC | |||||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||||
PROTECTION | 110~140% rated output power | |||||||||
OVERLOAD | Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 3.8 ~ 4.6V | 4.62 ~ 5.46V | 5.75 ~ 6.75V | 13.2 ~ 15.6V | 16.5 ~ 19.5V | 26.4 ~ 31.2V | 39.6 ~46.8V | 52.8 ~ 62.4V | 60 ~ 69V | |
Protection type :Shut down O/P voltage,re-power on to recover | ||||||||||
OVER TEMPERATURE | Protection type :Shut down O/P voltage, recovers automatically after temperature goes down | |||||||||
FUNCTION | DC OK SIGNAL(Optional) | Contact rating(max.):15Vdc/10mA resistive load | ||||||||
REDUNDANT(Optional) | For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system | |||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve") | ||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note.6) | SAFETY STANDARDS | UL 62368-1,TUV EN62368-1,EN60335-1(Except for 55V),CCC GB4943,BSMI CNS14336-1,EAC TP TC 004 approved,Design refer to EN61558-1,-2-16 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | |||||||||
EMC EMISSION | Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 | |||||||||
OTHERS | MTBF | 285 K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 220*62*31mm (L*W*H) | |||||||||
PACKING | 0.68 kg;16 pcs/11.88 kg/0.63CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | |||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||||
3. Tolerance :includes set up tolerance, line regulation and load regulation. | ||||||||||
4. Derating may be needed under low input voltages. Please check the derating curve for more details. | ||||||||||
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft) | ||||||||||
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies. | ||||||||||
(as available on http://www.meanwell.com) | ||||||||||
7. R type efficiency slightly less than the Blank type, according to the actual measurement. 8.lnrush current parameter has 10% tolerance. | ||||||||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell UHP-350 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].