Meanwell UHP-350R Series LED Switching Power Supply
$63.99 – $65.99
The Meanwell UHP-350R Series LED Switching Power Supply offers high efficiency, robust protection features, and wide compatibility for various LED display and lighting systems.
Model Number |
UHP-350R-3.3 ,UHP-350R-4.2 ,UHP-350R-5 ,UHP-350R-12 ,UHP-350R-15 ,UHP-350R-24 ,UHP-350R-36 ,UHP-350R-48 ,UHP-350R-55 |
---|
Meanwell UHP-350R Series Switching Power Supply Description
■ Features
‧Slim Low profile (31mm)
‧Fanness design,350W convection
‧Withstand 300VAC surge input for 5 seconds
‧Built-in active PFC function
‧-30~+70℃ working temperature
‧Protections: Short circuit / Overload / Over voltage / Over temperature
‧DC OK active signal and redundant function(option)
‧Operating altitude up to 5000 meters (Note.5)
‧LED indicator for power on
‧3 years warranty
■ Applications
‧Industrial automation machinery
‧Industrial control system
‧Mechanical and electrical equipment
‧Electronic instruments, equipment or apparatus
‧Household appliances
‧LED display application
‧Power Source Equipment for PoE(55V model)
■ Description
Meanwell UHP-350 series is a 350W single-output slim type power supply with 31mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V,48V, and 55V. ln addition to the high efficiency up to 94%, that the whole series operates from -30℃ ~ 70℃ under air convection without a fan. UHP-350 has complete protection functions and 5G anti-vibration capability;lt has complied with the international safety regulations such as TUV EN62368-1, EN60335-1, UL 62368-1 and GB4943. UHP-350 series serves as a high-performance power supply solution for various industrial applications.
Meanwell UHP-350R Series LED Switching Power Supply Specification:
MODEL | UHP-350-3.3 | UHP-350-4.2 | UHP-350-5 | UHP-350-12 | UHP-350-15 | UHP-350-24 | UHP-350-36 | UHP-350-48 | UHP-350-55 | |
---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V | 55V |
RATED CURRENT | 60A | 60A | 60A | 29.2A | 23.4A | 14.6A | 9.75A | 7.3A | 6.3A | |
RATED POWER | 198W | 252W | 300W | 350.4W | 351W | 350.4W | 351W | 350.4W | 350W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 3.2~3 .5V | 3.6~4 .4V | 4.5~5 .5V | 11.4~12 .6V | 14.3~15 .8V | 22.8~25 .2V | 34.2~37 .8V | 45.6~50 .4V | 45~58V | |
VOLTAGE TOLERANCE Note.3 | ±2 .0% | ±2 .0% | ±2 .0% | ±1 .0% | ±1 .0% | ±1 .0% | ±1 .0% | ±1 .0% | ±1 .0% | |
LINE REGULATION | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .3% | ±0 .3% | ±0 .3% | ±0 .3% | ±0 .3% | ±0 .3% | |
LOAD REGULATION | ±1 .0% | ±1 .0% | ±1 .0% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | ±0 .5% | |
SETUP, RISE TIME | 2000ms, 80ms/230VAC; 3000ms, 80ms/115VAC at full load;550ms/230VAC for 55V setup time | |||||||||
HOLD UP TIME (Typ.) | 10ms/230VAC 10ms/115VAC | |||||||||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR (Typ.) | PF≥0 .94/230VAC PF≥0 .98/115VAC at full load | |||||||||
EFFICIENCY (Typ.) | 88.50% | 89% | 90% | 91% | 92% | 94% | 94% | 94% | 94% | |
AC CURRENT (Typ.) | 4A/115VAC 2A/230VAC | |||||||||
INRUSH CURRENT (Typ.)Note8 | Cold start 30A/115VAC 60A/230VAC | |||||||||
LEAKAGE CURRENT | <0 .75mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 110~140% rated output power | ||||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 3.8 ~ 4 .6V | 4.62 ~ 5 .46V | 13.2 ~ 15.6V | 16.5 ~ 19.5V | 26.4 ~ 31 .2V | 39.6 ~46 .8V | 52.8 ~ 62 .4V | 60 ~ 69V | ||
Protection type :Shutdown O/P voltage,re-power on to recover | ||||||||||
OVER TEMPERATURE | Protection type :Shutdown O/P voltage, recovers automatically after temperature goes down | |||||||||
FUNCTION | DC OK SIGNAL(Optional) | Contact rating(max.) :15Vdc/10mA resistive load | ||||||||
REDUNDANT(Optional) | For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system | |||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve") | ||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||||
TEMP. COEFFICIENT | ±0 .03%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY &EMC (Note.6) | SAFETY STANDARDS | UL 62368-1,TUVEN62368-1,EN60335-1(Except for 55V),CCC GB4943,BSMI CNS14336-1,EACTPTC 004 approved,Design refer to EN61558-1,-2-16 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3 .75KVAC I/P-FG:2KVAC O/P-FG:1 .25KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | |||||||||
EMC EMISSION | Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3, BSMI CNS13438, EACTPTC 020 | |||||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8, 11;EN61000-6-2 (EN50082-2), heavy industry level ,criterialA,EACTPTC 020 | |||||||||
OTHERS | MTBF | 285 K hrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 220*62*31mm (L*W*H) | |||||||||
PACKING | 0.68 kg;16 pcs/11 .88 kg/0 .63CUFT | |||||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, ratedIoad and 25℃ of ambient temperature. | |||||||||
2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. | ||||||||||
3. ToIerance :incIudes set up toIerance,IinereguIation and IoadreguIation. | ||||||||||
4. Derating may be needed under Iowinput voItages. PIease check the derating curve for more detaiIs. | ||||||||||
5. The ambient temperature derating of 3.5℃/1000m with fanIess modeIs and of 5℃/1000m with fan modeIs for operating aItitude higher than 2000m(6500ft) | ||||||||||
6. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. The finaI equipment must be re-confirmed that it stiII meets EMC directives. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.” | ||||||||||
(asavaiIabIe on http://www.meanweII.com) | ||||||||||
7. R type efficiency sIightIy Iess than the BIank type, according to the actuaI measurement. 8.Inrush current parameter has 10% toIerance. | ||||||||||
※ Product Liability Disclaimer :For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
UHP-350(R)-Specification Download
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].
Reviews
There are no reviews yet.