Meanwell UHP-500 Series Switching Power Supply
$99.99 – $105.99
The Meanwell UHP-500 Series offers 500W output with various voltage options. Its fanless design and high efficiency make it perfect for industrial and LED display applications.
Model Number |
UHP-500-4.2 ,UHP-500-5 ,UHP-500-12 ,UHP-500-15 ,UHP-500-24 ,UHP-500-36 ,UHP-500-48 ,UHP-500-55 |
---|
Meanwell UHP-500 Series LED Display Power Supply Description
The Meanwell UHP-500 Series Switching Power Supply provides reliable 500W output with a slim design, suitable for industrial and LED display applications. It is available in 4.2V, 5V, 12V, 15V, 24V, 36V, 48V, and 55V options. The unit features a fanless design with a power factor correction (PFC) function, high efficiency up to 95%, and a wide operating temperature range from -30°C to +70°C.
Product Features:
● Power Output: 500W with multiple output voltage options (4.2V, 5V, 12V, 15V, 24V, 36V, 48V, and 55V).
● Efficiency: High efficiency up to 95% at full load.
● Design: Slim, fanless design ideal for compact installations.
● Temperature Range: Operates between -30°C and +70°C without a fan.
● Protections: Over-voltage, over-current, and over-temperature protection.
● Redundant Function: Optional parallel connection for increased reliability.
● Compliance: Meets international safety standards such as UL, TUV, EN62368-1, and more.
● Mounting: Easy installation with required aluminum plate (or similar surface).
Meanwell UHP-500 Series Switching Power Supply Specification:
MODEL | UHP-500-4.2 | UHP-500-5 | UHP-500-12 | UHP-500-15 | UHP-500-24 | UHP-500-36 | UHP-500-48 | UHP-500-55 | |
---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V | 55V |
RATED CURRENT | 80A | 80A | 41.7A | 33.4A | 20.9A | 13.9A | 10.45A | 8.9A | |
RATED POWER | 336W | 400W | 500.4W | 501W | 501.6W | 500.4W | 501.6W | 500W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 240mVp-p | 360mVp-p | 360mVp-p | 500mVp-p | |
VOLTAGE ADJ. RANGE Note.7 | 3.6~4.4V | 4.5~5.5V | 11.4~12.6V | 14.3~15.8V | 22.8~25.2V | 34.2~37.8V | 45.6~50.4V | 45~58V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | ±0.3% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time | ||||||||
HOLD UP TIME (Typ.) | 12ms/230VAC 12ms/115VAC | ||||||||
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 264VAC 127 ~ 370VDC | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
POWER FACTOR (Typ.) | PF≥0.95/230VAC PF≥0.98/115VAC at full load | ||||||||
EFFICIENCY (Typ.) | 89% | 90% | 94% | 94% | 94.50% | 95% | 95% | 95% | |
AC CURRENT (Typ.) | 4.85A/115VAC 2.6A/230VAC | ||||||||
INRUSH CURRENT (Typ.)Note9 | Cold start 30A/115VAC 60A/230VAC | ||||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||||||
PROTECTION | OVERLOAD | 110~140% rated output power | |||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 4.62 ~ 5.46V | 5.75 ~ 6.75V | 13.2 ~ 15.6V | 16.5 ~ 19.5V | 26.4 ~ 31.2V | 39.6 ~46.8V | 52.8 ~ 62.4V | 60 ~ 69V | |
Protection type :Shut down O/P voltage,re-power on to recover | |||||||||
OVER TEMPERATURE | Protection type :Shut down O/P voltage, recovers automatically after temperature goes down | ||||||||
FUNCTION | DC OK SIGNAL(Optional) | Contact rating(max.):30Vdc/1A resistive load | |||||||
REDUNDANT(Optional) | For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃(Refer to “Derating Curve") | |||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
SAFETY & EMC (Note.6) | SAFETY STANDARDS | UL 62368-1,TUV EN62368-1,EN60335-1(Except for 55V), CCC GB4943, BSMI CNS14336-1, EAC TP TC 004 approved;Design refer to EN61558-2-16 | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | ||||||||
EMC EMISSION | Compliance to EN55032,GB/T9254,Class B, EN61000-3-2,-3, BSMI CNS13438, EAC TP TC 020 | ||||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 | ||||||||
OTHERS | MTBF | 168K hrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 232*81*31mm (L*W*H) | ||||||||
PACKING | 0.905kg; 16pcs/15.48kg/0.82CUFT | ||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||||||
3. Tolerance :includes set up tolerance, line regulation and load regulation. | |||||||||
4. Derating may be needed under low input voltages. Please check the derating curve for more details. | |||||||||
5. The ambient temperature derating of 3.5℃/1000m is needed for operating altitude greater than 2000m(6500ft) | |||||||||
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, | |||||||||
please refer to EMl testing of component power supplies. (as available on http://www.meanwell.com) | |||||||||
7. Please refer to derating currve. | |||||||||
8. R type efficiency slightly less than the Blank type, according to the actual measurement. 9.lnrush current parameter has 10% tolerance. | |||||||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Download Resource:
Meanwell UHP-500 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].
Reviews
There are no reviews yet.