Meanwell XLG-100 Series Switching Power Supply

The Meanwell XLG-100 Series is a 100W LED driver with 92.5% efficiency, IP67 protection, and versatile dimming options for reliable LED lighting solutions.

Model Number

XLG-100-12-A

,

XLG-100-24-A

,

XLG-100-H-A

,

XLG-100-H-AB

,

XLG-100-L-A

This product is currently out of stock and unavailable.

SKU: MWXLG100XXX Categories: ,
MeanWell
Description

Meanwell XLG-100 Series Switching Power Supply Description

The Meanwell XLG-100 Series is a 100W AC/DC LED driver designed to deliver constant power output with superior reliability. It operates within a wide input voltage range of 100–305VAC and achieves high efficiency of up to 92.5%. Featuring a durable metal housing with IP67 ingress protection, it is suitable for harsh indoor and outdoor environments. With advanced dimming capabilities and compliance with international safety standards, the XLG-100 Series is a versatile and reliable solution for diverse LED lighting systems. The series ensures safety with surge protection and long operational life exceeding 50,000 hours.

Product Features:
● Constant Power Mode: Maintains consistent power for reliable LED performance.
● Wide Input Voltage Range: Operates from 100–305VAC, suitable for various applications.
● High Efficiency: Up to 92.5%, minimizing energy loss.
● Durable Metal Housing: IP67-rated, waterproof, and dustproof for challenging environments.
● Dimming Options: 3-in-1 dimming (0–10VDC, PWM signal, resistance).
● Wide Operating Temperature Range: -40°C to +90°C for extended durability.
● Surge Protection: Withstands surges of 6KV/4KV for added safety.
● Long Lifetime: Operates reliably for over 50,000 hours with a 5-year warranty.
● Safety Compliance: Meets IEC61347, GB19510.1, UL8750, and other safety standards.

Applications:
● LED street lighting
● Floodlighting
● Architectural lighting
● Horticultural lighting
● Bay lighting
● Stage and studio lighting
● Skyscraper lighting
● Hazardous locations (Type HL, Class I, Division 2)

Meanwell XLG-100 Series Switching Power Supply Specification:

MODELXLG-100 -12-□□XLG-100 -24-□□
OUTPUTDC VOLTAGE12V24V
CONSTANT CURRENT REGION Note.28.4~ 12V16.8~ 24V
RATED CURRENT (Default)8A4A
RATED POWER96W96W
RIPPLE & NOISE (max.) Note.3150mVp-p240mVp-p
CURRENT ADJ RANGEAdjustable for A-Type only (via the built-in potentiometer)
4 ~ 8A2~4A
VOLTAGE TOLERANCE Note.4±3.0%±2.0%
LINE REGULATION±0.5%±0.5%
LOAD REGULATION±2%±1%
SETUP, RISE TIME Note.6500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
HOLD UP TIME (Typ.)12ms/ 230VAC 12ms/ 115VAC
INPUTVOLTAGE RANGE Note.5100 ~ 305VAC 142 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE47 ~ 63Hz
POWER FACTORPF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC@full load
TOTAL HARMONIC DISTORTIONTHD< 10%(@load50%/115VC,230VAC; @load75%/277VAC)
EFFICIENCY (Typ.)92%92%
AC CURRENT1.1A / 115VAC 0.5A / 230VAC 0.42A/277VAC
INRUSH CURRENT(Typ.)COLD START 50A(twidth=300μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER8units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA / 277VAC
NO LOADNo load power consumption <0.5W(for standard version)
POWER CONSUMPTION
PROTECTIONOVER CURRENT95 ~ 108%
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITHiccup mode or Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE13.5 ~ 18V27 ~ 34V
Shut down output voltage, re-power on to recover
INPUT OVER VOLTAGE Note.7320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage, recovers automatically after fault condition is removed)
Can survive input voltage stress of 440Vac for 48 hours
OVER TEMPERATUREShut down output voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.Tcase=-40 ~ +90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.Tcase=+90
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +80, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/ (0 ~ 60)
VIBRATION10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
EMC SAFETY &SAFETY STANDARDS Note.7UL8750(type”HL”), UL879, CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB19510.1,GB19510.14;EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-100I type only);NOM-058-SCFI-2017(except for Blank type); IP67 approved
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
EMC EMISSIONParameterStandardTest Level/Note
ConductedBS EN/EN55015(CISPR15) ,GB/T 17743-----
RadiatedBS EN/EN55015(CISPR15) ,GB/T 17743-----
Harmonic CurrentBS EN/EN61000-3-2 , GB17625.1Class C @load≥50%
Voltage FlickerBS EN/EN61000-3-3-----
EMC IMMUNITYBS EN/EN61547
ParameterStandardTest Level/Note
ESDBS EN/EN61000-4-2Level 3, 8KV air ; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 3
EFT/BurstBS EN/EN61000-4-4Level 3
SurgeBS EN/EN61000-4-54KV/Line-Line 6KV/Line-Earth(6K/10K option)
ConductedBS EN/EN61000-4-6Level 3
Magnetic FieldBS EN/EN61000-4-8Level 4
Voltage Dips and InterruptionsBS EN/EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
OTHERSMTBF2782.6K hrs min. Telcordia SR-332 (Bellcore) ; 276.4Khrs min. MIL-HDBK-217F (25)
DIMENSION140*63*32mm (L*W*H)
PACKING0.58Kg;24pcs /15Kg /0.85CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. Input voltage only for XLG-100 I series, and I series without UL/CSA certificate.
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
9. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.
12. Products sourced from the Americas regions may not have the PSE/CCC/BIS/KC logo. Please contact your MEAN WELL sales for more information.
13. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
14. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:XLG-100-SPEC 2024-03-12

Download Resource:
Meanwell XLG-100 Series Switching Power Supply Specification

Get a Bulk Price Quote

    Shipping & Delivery

    ①Shipping Fee
    We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.

    ②Handling Time
    Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.

    ③Delivery Time
    Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.

    ④Customs & Duties
    Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.

    ⑤Tracking Your Order
    You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.

    For more details, please see our [Complete Shipping Policy].