Meanwell XLG-200 Series Switching Power Supply
The Meanwell XLG-200 Series is a 200W LED driver with 94% efficiency, IP67 protection, and advanced dimming options, perfect for industrial lighting.
Model Number |
XLG-200-12-A ,XLG-200-24-A ,XLG-200-H-A ,XLG-200-H-AB |
---|
Meanwell XLG-200 Series Switching Power Supply Description
The Meanwell XLG-200 Series is a high-performance 200W AC/DC LED driver designed with constant power mode output. It supports a wide input voltage range of 100–305VAC and achieves efficiency levels of up to 94%, ensuring reliable operation and energy efficiency. Its robust metal housing with IP67 protection makes it suitable for indoor and outdoor installations. The series offers advanced dimming functionality, including 3-in-1 dimming, and complies with the latest international safety standards, such as UL8750 and IEC61347. It guarantees long-lasting performance, exceeding 50,000 hours of operation.
Product Features:
● Constant Power Mode: Ensures stable and reliable power output across varying applications.
● Wide Input Voltage Range: Operates seamlessly from 100–305VAC.
● High Efficiency: Up to 94%, minimizing energy waste and heat output.
● Durable Metal Housing: IP67-rated for water and dust resistance.
● Advanced Dimming Options: Supports 3-in-1 dimming (0–10VDC, PWM signal, resistance).
● Surge Protection: Provides robust protection with 6KV/4KV surge resistance.
● Wide Operating Temperature: Functions reliably in -40°C to +90°C environments.
● Long Lifetime: Operates beyond 50,000 hours with a 5-year warranty.
● Safety Compliance: Meets UL8750, IEC61347, GB19510, and other global safety standards.
Applications:
● Street lighting
● Floodlighting
● Architectural lighting
● Horticultural lighting
● Industrial lighting
● Bay lighting
● Hazardous locations (Type HL, Class I, Division 2)
Meanwell XLG-200 Series Switching Power Supply Specification:
MODEL | XLG-200 -12-□□ | XLG-200 -24-□□ | |||
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 24V | ||
CONSTANT CURRENT REGION Note.2 | 8.4~ 12V | 16.8~ 24V | |||
RATED CURRENT (Default) | 16A | 8.3A | |||
RATED POWER | 192W | 199.2W | |||
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 240mVp-p | |||
CURRENT ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) | ||||
8 ~ 16A | 4.15 ~ 8.3A | ||||
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±2.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±2% | ±1% | |||
SETUP, RISE TIME Note.6 | 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC | ||||
HOLD UP TIME (Typ.) | 10ms/ 230VAC 10ms/ 115VAC | ||||
INPUT | VOLTAGE RANGE Note.5 | 100 ~ 305VAC 142 ~ 431VDC | |||
(Please refer to "STATIC CHARACTERISTIC" section) | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load | ||||
TOTAL HARMONIC DISTORTION | THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC) | ||||
EFFICIENCY (Typ.) | 92% | 94% | |||
AC CURRENT | 2.2A / 115VAC 1.1A / 230VAC 0.9A/277VAC | ||||
INRUSH CURRENT(Typ.) | COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD | No load power consumption <0.5W(for standard version) | ||||
POWER CONSUMPTION | |||||
PROTECTION | OVER CURRENT | 110~160% for CV type,95~108% for other type | |||
CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 13.5 ~ 18V | 27 ~ 34V | |||
Shut down output voltage, re-power on to recover | |||||
INPUT OVER VOLTAGE | 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed) | ||||
Can survive input voltage stress of 440Vac for 48 hours(Input over voltage only for XLG-200I series) | |||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recover | ||||
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | |||
MAX. CASE TEMP. | Tcase=+90℃ | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
EMC SAFETY & | SAFETY STANDARDS Note.7 | UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384;GB19510.1, GB19510.14;EAC TP TC 004;J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-200I type only );NOM-058-SCFI-2017(except for Blank type);IP67 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION | Parameter | Standard | Test Level/Note | ||
Conducted | BS EN/EN55015(CISPR15) ,GB/T 17743 | ----- | |||
Radiated | BS EN/EN55015(CISPR15) ,GB/T 17743 | ----- | |||
Harmonic Current | BS EN/EN61000-3-2 ,GB17625.1 | Class C @load≥50% | |||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | |||
EMC IMMUNITY | BS EN/EN61547 | ||||
Parameter | Standard | Test Level/Note | |||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||
Radiated | BS EN/EN61000-4-3 | Level 3 | |||
EFT/Burst | BS EN/EN61000-4-4 | Level 3 | |||
Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth(6K/10K option) | |||
Conducted | BS EN/EN61000-4-6 | Level 3 | |||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, | |||
>95% interruptions 250 periods | |||||
OTHERS | MTBF | 2300.1K hrs min. Telcordia SR-332 (Bellcore) ; 200.7Khrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 199*63*35.5mm (L*W*H) | ||||
PACKING | 0.85Kg;16pcs /14.2Kg /0.75CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature. | ||||
2. Please refer to "DRIVING METHODS OF LED MODULE"(Except for CV-type). | |||||
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
4. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. | |||||
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. | |||||
7. Only CE/ENEC/CB is available for CV-type. XLG-200I series without UL/CSA certificate. | |||||
8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | |||||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) | |||||
9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly | |||||
tc point (or TMP, per DLC), is about 75℃ or less. | |||||
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com | |||||
11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | |||||
12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information. | |||||
13. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf | |||||
14. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. | |||||
15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details. | |||||
16. For A/AB type need to consider build in using to comply with Type HL application. | |||||
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:XLG-200-SPEC 2024-10-11 |
Download Resource:
Meanwell XLG-200 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].