Meanwell XLG-320 Series Switching Power Supply
The Meanwell XLG-320 Series Switching Power Supply is a 315W LED driver featuring constant power mode, IP67 protection, and 3-in-1 dimming, ideal for diverse LED applications.
Model Number |
XLG-320-H-AB ,XLG-320-V-A ,XLG-320-48-ABV ,XLG-320-L-A |
---|
Meanwell XLG-320 Series Switching Power Supply Description
The Meanwell XLG-320 Series Switching Power Supply is a 315W LED AC/DC driver designed for reliable performance in various LED lighting applications. With a constant power mode, wide input voltage range, and IP67 ingress protection, it is ideal for both indoor and outdoor use. This series features advanced dimming options, robust surge protection, and a durable metal housing, making it suitable for demanding environments and high-performance lighting systems.
Product Features:
● Constant Power Mode: Provides full power output in a wide operating range (75%–100%).
● Wide Input Voltage Range: Operates from 100–305VAC, supporting global applications.
● High Efficiency: Up to 94.5%, ensuring energy savings and reliability.
● Robust Design: Durable metal case with IP67 ingress protection for outdoor and harsh environments.
● Dimming Options: 3-in-1 dimming capability (0–10VDC, 10V PWM, and resistance dimming) for flexible lighting control.
● Surge Protection: Built-in 6KV/4KV surge protection for enhanced durability.
● Advanced Safety Features: Includes overload, short circuit, overvoltage, and overtemperature protections.
● Longevity: Lifetime exceeds 50,000 hours, backed by a 5-year warranty.
Meanwell XLG-320 Series Switching Power Supply Specification:
MODEL | XLG-320-L- | XLG-320-M- | XLG-320-H- | XLG-320-V- | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | RATED CURRENT (Default) | 1400mA | 2800mA | 5600mA | 13A/24V | ||||||||||
RATED POWER Note.10 | 315W | 310.8W | 312W | 24V/312W, 12V/216W | |||||||||||
CONSTANT CURRENT REGION | 150~300V | 74 ~ 148V | 30 ~ 56V | NC | |||||||||||
OUTPUT VOLTAGE ADJ. RANGE | NC | NC | NC | 24V or 12V | |||||||||||
FULL POWER CURRENT RANGE | 1050~1400mA | 2100~2800mA | 5570~7420mA | 13~18A(24V/13A , 12V/18A) | |||||||||||
OPEN CIRCUIT VOLTAGE (max.) | 340V | 180V | 60V | NC | |||||||||||
CURRENT ADJ. RANGE | 500~1400mA | 1050~2800mA | 2800~7420mA | NC | |||||||||||
CURRENT RIPPLE | 5.0% max. @rated current | 5.0 max. @rated current | 5.0% max. @rated current | NC | |||||||||||
CURRENT TOLERANCE | ±5% | ±5% | ±5% | NC | |||||||||||
RIPPLE & NOISE(max.) | NC | NC | NC | 240mV p-p | |||||||||||
VOLTAGE TOLERANCE | NC | NC | NC | ±3% | |||||||||||
LINE REGULATION | NC | NC | NC | ±0 .5% | |||||||||||
LOAD REGULATION | NC | NC | NC | ±2% | |||||||||||
SET UP TIME Note.9 | 500ms/230VAC , 1200ms/115VAC | ||||||||||||||
RISE TIME,HOLD UP TIME (Typ.) | 160ms , 10ms/230VAC/115VAC(only for V-type) | ||||||||||||||
INPUT | VOLTAGE RANGE Note.2 | 100 ~ 305VAC 142VDC ~ 431VDC | |||||||||||||
(Please refer to "STATIC CHARACTERISTIC" ang “ DRIVING METHODS OF LED MODULE"section) | |||||||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||||
POWER FACTOR (Typ.) | PF≥0 .98 / 115VAC , PF≥0 .95 / 230VAC , PF≥0 .92 / 277VAC at full load (Please refer to "Power Factor Characteristic" section) | ||||||||||||||
TOTAL HARMONIC DISTORTION | THD< 10% @ load≥50% at 115VAC/230VAC , THD<15%@Load>75% at 277VAC; Please refer to “TOTAL HARMONIC DISTORTION (THD) ” section | ||||||||||||||
EFFICIENCY (Typ.) | 94.50% | 93.50% | 92.50% | 93% | |||||||||||
AC CURRENT (Typ.) | 3A / 120VAC 1.6A / 230VAC 1.3A / 277VAC | ||||||||||||||
INRUSH CURRENT(Typ.) | COLD START 45A(twidth=1200μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||||||||||||
MAX. NO. of PSUs on 16A CIRCUIT BREAKER | 2 unit(circuit breaker of type B) / 4 units(circuit breaker of type C) at 230VAC | ||||||||||||||
LEAKAGE CURRENT | <0 .75mA / 277VAC | ||||||||||||||
STANDBY POWER | Standby power consumption <0 .5W for AB-Type(Dimming OFF) | ||||||||||||||
CONSUMPTION Note.5 | |||||||||||||||
PROTECTION | SHORT CIRCUIT | Hiccup mode or Constant current limiting , recovers automatically after fault condition is removed | |||||||||||||
OVER VOLTAGE | 350 ~ 380V | 190 ~ 220V | 63 ~ 78V | 27 ~ 34V | |||||||||||
Shut down output voltage , re-power on to recovery | |||||||||||||||
OVER TEMPERATURE Note.11 | L/M/H-Type: Tcase>85℃±5℃,derate power automatically V-Type: Shut down output voltage , re-power on to recover | ||||||||||||||
OVER LOAD Note.10 | 108~135%(only for V-type) | ||||||||||||||
Hiccup mode or Constant current limiting , recovers automatically after fault condition is removed | |||||||||||||||
WORKING TEMP. | Tcase=-40 ~ +85℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) | ||||||||||||||
MAX. CASE TEMP. | Tcase=+85℃ | ||||||||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||||||||||||
ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH non-condensing | |||||||||||||
TEMP. COEFFICIENT | ±0 .03%/℃ (0 ~ 60℃) | ||||||||||||||
VIBRATION | 10 ~ 500Hz , 5G 12min./1cycle, period for 72min. each along X , Y, Z axes | ||||||||||||||
SAFETY & EMC | SAFETY STANDARDS | UL8750(type” HL”) , CSAC22 .2 No. 250. 13-12; ENEC BS EN/EN61347-1 , BS EN/EN61347-2-13 independent , BS EN/EN62384 , EN/EN60335-1 compliant to EN 60335-2-89 Annex BB , EN 60335-2-24 Annex CC;GB19510 .1 , GB19510 . 14;EACTPTC 004; IP67; | |||||||||||||
IS15885(Part2/Sec13)(except for blank type) , KC61347-1 ,KC61347-2-13 approved | |||||||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3 .75KVAC I/P-FG:2KVAC O/P-FG:1 .5KVAC | ||||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG , O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | ||||||||||||
Conducted | BS EN/EN55015(CISPR15) , GB/T 17743 | ----- | |||||||||||||
Radiated | BS EN/EN55015(CISPR15) , GB/T 17743 | ----- | |||||||||||||
Harmonic Current | BS EN/EN61000-3-2 , GB17625 . 1 | Class C @load≥50% | |||||||||||||
Voltage Flicker | BS EN/EN61000-3-3 | ----- | |||||||||||||
BS EN/EN61547 | |||||||||||||||
Parameter | Standard | Test Level / Note | |||||||||||||
ESD | BS EN/EN61000-4-2 | Level 3 , 8KV air ; Level 2 , 4KV contact | |||||||||||||
EMC IMMUNITY | Radiated | BS EN/EN61000-4-3 | Level 2 | ||||||||||||
EFT / Burst | BS EN/EN61000-4-4 | Level 3 | |||||||||||||
Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth | |||||||||||||
Conducted | BS EN/EN61000-4-6 | Level 2 | |||||||||||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4 | |||||||||||||
Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0 .5 periods , 30% dip 25 periods , >95% interruptions 250 periods | |||||||||||||
MTBF | 1476.4K hrs min. Telcordia SR-332(Bellcore) ; 168.1 K hrs min. MIL-HDBK-217F (25℃) | ||||||||||||||
OTHERS | DIMENSION | 246*77*39.5mm (L*W*H) | |||||||||||||
PACKING | 1.45Kg;9pcs/14Kg/0 .76CUFT | ||||||||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature. | ||||||||||||||
2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. | |||||||||||||||
3. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | |||||||||||||||
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) | |||||||||||||||
4. This series meets the typical life expectancy >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is 75℃ or less. | |||||||||||||||
5. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. | |||||||||||||||
6. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com | |||||||||||||||
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | |||||||||||||||
8. For any application note and IP waterproof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf | |||||||||||||||
9. Products sourced from the Americas regions may not have the ENEC/CCC/KC logo. Please contact your MEAN WELL sales for more information. | |||||||||||||||
10.The output voltage of the V Type default is 24V, for 12V output, please adjust SVR by clockwise direction to the end, otherwise the OLP point is not within the specification range. 11.When the secondary OTP fails, there is also a primary OTP, which is protected by Shut down output voltage, re-power on to recovery for the H/M/L-type. | |||||||||||||||
12. When the current adjustment is more than 110% of the rated current, it will be enter the Protection state. | |||||||||||||||
13. V,H type:RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. M,L type:RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. | |||||||||||||||
14. It may has an over-shoot status at output current when AC On/Off operate with lower Vf and lower loading conditions. | |||||||||||||||
15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details. | |||||||||||||||
16. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||||||||||||
17. Please refer to "DRIVING METHODS OF LED MODULE". | |||||||||||||||
※ Product Liability Disclaimer :For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:XLG-320-SPEC 2024- 03- 12 |
Download Resource:
Meanwell XLG-320 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].
Reviews
There are no reviews yet.