Meanwell XLG-50 Series Switching Power Supply
$18.99 – $19.99Price range: $18.99 through $19.99
The Meanwell XLG-50 Series is a 50W LED driver offering 90% efficiency, IP67 protection, and multiple dimming options, ideal for LED lighting systems.
| Model Number | XLG-50-A, XLG-50-AB |
|---|
Meanwell XLG-50 Series Switching Power Supply Description
The Meanwell XLG-50 Series is a 50W AC/DC LED driver designed to provide constant power output, ensuring consistent and efficient performance for LED lighting systems. Operating within a wide input voltage range of 90–305VAC, the XLG-50 Series achieves high efficiency of up to 90%. Featuring a robust metal housing with an IP67 protection rating, it is suitable for both indoor and outdoor installations. The XLG-50 Series supports a wide temperature range of -40°C to +90°C and utilizes air convection for cooling, eliminating the need for fans. Additionally, its multiple dimming methodologies provide design flexibility for LED lighting systems. The series complies with IEC61347, GB19510.1, and UL8750 international safety standards, offering safe and reliable operation.
Product Features:
● Constant Power Mode Output: Ensures stable LED lighting performance.
● Input Voltage Range: 90–305VAC, accommodating a wide range of power conditions.
● High Efficiency: Up to 90%, reducing energy waste and operating costs.
● Robust Design: Metal housing with functional grounding for durability.
● Wide Temperature Range: Operates reliably between -40°C and +90°C.
● IP67 Rating: Waterproof and dustproof, suitable for indoor and outdoor applications.
● Dimming Options: Supports 3-in-1 dimming (0–10VDC, PWM signal, resistance adjustment).
● Energy Saving: Low standby power consumption (<0.5W).
● Safety Compliance: Meets IEC61347, GB19510.1, UL8750 safety standards.
● Applications: Ideal for LED street lighting, architectural lighting, bay lighting, floodlighting, and hazardous locations (Type HL, Class I, Division 2).
Applications:
● LED street lighting
● Architectural lighting
● LED bay lighting
● Floodlighting
● Hazardous locations (Class I, Division 2)
Meanwell XLG-50 Series Switching Power Supply Specification:
| MODEL | XLG-50 -□□ | |||||
|---|---|---|---|---|---|---|
| OUTPUT | RATED CURRENT (Default) | 1A | ||||
| CONSTANT CURRENT REGION Note.2 | 22 ~54V | |||||
| RATED POWER | 100VAC ~ 305VAC | |||||
| 50W | ||||||
| CURRENT RIPPLE | 5.0% max. @rated current | |||||
| OPEN CIRCUIT VOLTAGE (max.) | 57V | |||||
| CURRENT ADJ. RANGE | 0.53 ~ 2.1A | |||||
| SETUP, RISE TIME Note.3 | 500ms, 100ms/115VAC, 230VAC | |||||
| INPUT | VOLTAGE RANGE Note.4 | 90 ~ 305VAC 127 ~ 431VDC | ||||
| (Please refer to "STATIC CHARACTERISTIC" section) | ||||||
| FREQUENCY RANGE | 47 ~ 63Hz | |||||
| POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load | |||||
| (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) | ||||||
| TOTAL HARMONIC DISTORTION | THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC) | |||||
| (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) | ||||||
| EFFICIENCY (Typ.) Note.10 | 90% | |||||
| AC CURRENT | 0.57A / 115VAC 0.29A / 230VAC 0.24A/277VAC | |||||
| INRUSH CURRENT(Typ.) | COLD START 50A(twidth=350μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||
| MAX. No. of PSUs on 16A CIRCUIT BREAKER | ||||||
| 5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC | ||||||
| LEAKAGE CURRENT | <0.75mA / 277VAC | |||||
| NO LOAD / STANDBY POWER CONSUMPTION | No load power consumption <0.5W for A, <0.75W for I series Standby power consumption <0.5W for AB-Type(Dimming OFF) | |||||
| PROTECTION | OVER POWER | 110-150% Over Power Protection, recovers automatically after fault condition is removed | ||||
| SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed | |||||
| OVER TEMPERATURE | Hiccup mode, recovers automatically after fault condition is removed | |||||
| INPUT OVER VOLTAGE Note.8 | 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed) | |||||
| Can survive input voltage stress of 440Vac for 48 hours | ||||||
| ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | ||||
| MAX. CASE TEMP. | Tcase=+90℃ | |||||
| WORKING HUMIDITY | 20 ~ 95% | |||||
| STORAGE TEMP. | -40 ~ +80℃ | |||||
| TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | |||||
| VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||
| SAFETY & EMC | SAFETY STANDARDS Note.8 | UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC AS/NZS IEC BS EN/EN61347-1, AS/NZS BS EN/EN61347-2-13 independent, BS EN/EN62384; IP67; GB19510.1, GB19510.14, EAC TP TC 004,J61347-1(H29), J61347-2-13(H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)( for XLG-50I type only); NOM-058-SCFI-2017 approved | ||||
| WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC | |||||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||
| EMC EMISSION | Parameter | Standard | Test Level/Note | |||
| Conducted | BS EN/EN55015(CISPR15) ,GB/T 17743 | ----- | ||||
| Radiated | BS EN/EN55015(CISPR15) ,GB/T 17743 | ----- | ||||
| Harmonic Current | BS EN/EN61000-3-2 ,GB17625.1 | Class C @load≥50% | ||||
| Voltage Flicker | BS EN/EN61000-3-3 | ----- | ||||
| EMC IMMUNITY | BS EN/EN61547 | |||||
| Parameter | Standard | Test Level/Note | ||||
| ESD | BS EN/EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | ||||
| Radiated | BS EN/EN61000-4-3 | Level 3 | ||||
| EFT/Burst | BS EN/EN61000-4-4 | Level 3 | ||||
| Surge | BS EN/EN61000-4-5 | 4KV/Line-Line 6KV/Line-Earth | ||||
| Conducted | BS EN/EN61000-4-6 | Level 3 | ||||
| Magnetic Field | BS EN/EN61000-4-8 | Level 4 | ||||
| Voltage Dips and Interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, | ||||
| >95% interruptions 250 periods | ||||||
| OTHERS | MTBF | 3931.6 K hrs min. Telcordia SR-332 (Bellcore) 394.6Khrs min. | MIL-HDBK-217F (25℃) | |||
| DIMENSION | 105*63*30mm (L*W*H) | |||||
| PACKING | 0.41Kg;24pcs/ 10.5Kg/0.81CUFT for A-type 0.42Kg;24pcs/ 11Kg/0.81CUFT for AB-type | |||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature. | |||||
| 2. Please refer to "DRIVING METHODS OF LED MODULE". | ||||||
| 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. | ||||||
| 4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. | ||||||
| 5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. | ||||||
| (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) | ||||||
| 6. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly | ||||||
| tc point (or TMP, per DLC), is about 75℃ or less. | ||||||
| 7. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com | ||||||
| 8. Input over voltage only for XLG-50 I series ,and I series without UL/CSA certificate. | ||||||
| 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). | ||||||
| 10. Only for XLG-50-A | ||||||
| 11. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information. | ||||||
| 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf | ||||||
| 13. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||
| 14. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. | ||||||
| 15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details. | ||||||
| ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx | ||||||
Download Resource:
Meanwell XLG-50 Series Switching Power Supply Specification
①Shipping Fee
We offer a fixed shipping fee of $78 per order, regardless of size or weight, making shipping costs predictable and manageable.
②Handling Time
Orders for in-stock items are processed within 24 hours. Some items may require an additional 48-72 hours for processing, and we will notify you if this is the case.
③Delivery Time
Our typical delivery time is 3-7 days, depending on your location. In rare cases of delays due to weather, regulations, or holidays, we appreciate your understanding.
④Customs & Duties
Customs duties, taxes, and other import fees are the responsibility of the recipient. For specific requirements, please inform us before shipping.
⑤Tracking Your Order
You will receive a tracking number once your package is shipped. If you experience any issues, please contact us for assistance.
For more details, please see our [Complete Shipping Policy].






























































Reviews
There are no reviews yet.